FINGERS – REMOVAL AND DISASSEMBLY FOR CLEANING

FINGERS – REMOVAL AND DISASSEMBLY FOR CLEANING

!

CAUTION:

Oven must be cool before proceeding.

 

 

DISASSEMBLY

RETAINING

TABS

1.Release ¼-turn fasteners (2 per panel) then pull back the panel. Lift panel off lower retaining tabs.

2.Lift finger assembly to clear hanger on front wall of oven. Then slide to the rear and swing out. Remove finger assembly from oven.

DISASSEMBLE FINGERS FOR CLEANING

3.Slide finger cover from housing. Lift out inner Columnating Plate.

REASSEMBLY

4. Reassemble in reverse order.

NOTE: Check to insure that the holes in the columnating plate are lined up with the holes in the orifice panel.

5.Reinstall fingers in the oven. Be sure that they are fully seated over the plenum flanges and the holes are pointing toward the conveyor.

6.Reinstall cover panels (see #1).

COLUMNATING PLATE

ORIFICE

PANEL

12