IMPINGER ADVANTAGE ELECTRIC OVENS
SERIAL NUMBER N28654 AND ABOVE (OVENS WITH PUSH BUTTON CONTROLS)
SYMPTOM | POSSIBLE CAUSE | EVALUATION |
Oven fan will not run | Incoming power supply | Check circuit breaker, reset if required. Check power |
|
| plug to be sure it is firmly in receptacle. Measure |
|
| incoming power, call power co. if required. |
| Fuse, 10 Amp | Check, replace if necessary. |
| Fuse holder | Check, replace if necessary. |
| Thermostat, control | Terminals are normally closed, open at 130°F (55°C). If |
| box | open, reset and test for proper operation. If thermostat |
|
| will not hold, and control box temperature is not |
|
| exceeding 130°F (55°C), replace thermostat. |
| Switch, oven power | Check for line voltage supplied to switch. If no voltage is |
|
| present, trace wiring back to fuse holder. Check |
|
| continuity between switch terminals. Replace switch as |
|
| needed. |
| Motor, main fan | Check for line voltage supplied to motor. If no voltage is |
|
| present, trace wiring back to oven power switch. Check |
|
| motor for opens, shorts or grounds. |
|
| WITH POWER OFF: Turn fan blade to check for locked |
|
| rotor. |
No control box cooling | Incoming power supply | Check circuit breaker, reset if required. Check power |
|
| plug to be sure it is firmly in receptacle. Measure |
|
| incoming power, call power co. if required. |
| Fuse, 10 Amp | Check, replace if necessary. |
| Fuse holder | Check, replace if necessary. |
| Switch, oven power | Check for line voltage supplied to switch. If no voltage |
|
| is present, trace wiring back to fuse holder. Check |
|
| continuity between switch terminals. Replace switch as |
|
| needed. |
| Cooling fan | Check for supply voltage to the cooling fan. If no |
|
| voltage is present, trace wiring back to the fuse holder. |
|
| If voltage is present and motor does not run, check |
|
| motor for opens shorts or grounds. |
|
| WITH POWER OFF: Check for locked rotor. |
No automatic control | Incoming power supply | Check circuit breaker, reset if required. Check power |
box cooling |
| plug to be sure it is firmly in receptacle. Measure |
|
| incoming power, call power co. if required. |
| Cooling fan thermostat | Check cooling fan thermostat (thermostat closes at |
|
| 120°F and opens at 100°F). With cooling fan thermostat |
|
| |
Control box cooling fan | Cooling fan thermostat | See “Cooling fan thermostat” (NOTE: Thermostat will |
continues to run |
| remain closed if control box temperature remains above |
|
| 120°F. |
Oven will not heat | Main fan | If not operating, refer to “Oven fan will not run” |
| Air pressure switch | Check air switch terminals for supply voltage to |
|
| terminals NO and COM. If voltage is present on one side |
|
| only, check for air tube blockage or misalignment. If |
|
| these are okay, adjust air pressure switch or replace |
|
| switch as needed. |
| Oven cavity | Terminals are normally closed, opens at 660°F (350°C). |
| thermostat | If open, reset and test oven for proper operation. If |
|
| thermostat will not hold for maximum temperature, and |
|
| oven is not exceeding control setting, check for proper |
|
| location of the capillary bulb in its spring holder. If above |
|
| checks are okay, replace |
| Control transformer | Check for supply voltage to primary of control |
|
| transformer. If no voltage is present, trace wiring back to |
|
| oven power switch. If voltage is present, check for |
6 | Impinger I |