SEQUENCE OF OPERATION
IMPINGER ADVANTAGE
SERIAL NUMBER N28654 AND ABOVE (OVENS WITH PUSH BUTTON CONTROLS)
MODEL | 230/400 VAC 50 HZ. | 3 PHASE |
|
| |
POWER SUPPLY | Electrical power is to be supplied to the oven by a five conductor | |
| service. |
|
| Brown conductor is hot. |
|
| Black conductor is hot. |
|
| Black conductor is hot. |
|
| Blue conductor is neutral. |
|
| Green conductor is ground. |
|
CONTROL BOX AUTO | When the temperature in the control box reaches 120°F ± 3°F (48.9°C | |
COOL DOWN | ± 1.7°C), the cooling fan thermostat will switch power to the control | |
| box cooling fan. The thermostat will interrupt power to the cooling fan | |
| when the control box temperature falls to 100°F ± 3°F (37°C ± 1.7°C). | |
MAIN FAN CIRCUIT | Electrical power is permanently supplied through three 50 A fuses to | |
| the normally open contacts of the | |
| supplied, through the 10 Amp motor and control fuse, through the | |
| normally closed control box | |
| oven power switch. Power is also supplied to the control box cooling | |
| fan thermostat. Closing the oven power switch supplies line voltage to | |
| the main fan motor. Closing the oven power switch also supplies line | |
| voltage to the heat circuit and to the primary of the oven control | |
| transformer. |
|
HEAT CIRCUIT | Closing the oven power switch supplies line voltage through the main | |
| fan air pressure switch, through the normally closed oven cavity | |
| thermostat, to the oven control |
|
TEMPERATURE CONTROL | Closing the oven power switch supplies line voltage, through the EMI | |
| filter, to the primary of the control transformer and through the air | |
| pressure switch and oven cavity | |
| Secondary voltage, 24VAC, is supplied to the oven control. The oven | |
| control is set to desired temperature. The thermocouple will provide | |
| varying millivolts to the oven control. The oven control supplies line | |
| voltage to the heat contactor at intermittent intervals to maintain | |
| desired temperature. The display on the oven control will indicate | |
| when the heat contactor is energized. |
|
| NOTE: The display also indicates oven temperature. | |
CONVEYOR DRIVE | Closing the oven power switch supplies line voltage to the conveyor | |
| motor and to the primary of the control transformer. Secondary | |
| voltage, 24VAC, is supplied to the oven control. Setting the oven | |
| control to the desired time outputs voltage, through a reversing switch, | |
| to the conveyor motor. |
|
| NOTE: The conveyor system uses a hall effect sensor and magnet to | |
| prove operation of the conveyor motor. If the motor is not running, | |
| “BELT JAM” is indicated on the display. |
2 | Impinger I |