SEQUENCE OF OPERATION

IMPINGER ADVANTAGE

SERIAL NUMBER N28654 AND ABOVE (OVENS WITH PUSH BUTTON CONTROLS)

MODEL 1421-000-E

230/400 VAC 50 HZ.

3 PHASE

 

 

POWER SUPPLY

Electrical power is to be supplied to the oven by a five conductor

 

service.

 

 

Brown conductor is hot.

 

 

Black conductor is hot.

 

 

Black conductor is hot.

 

 

Blue conductor is neutral.

 

 

Green conductor is ground.

 

CONTROL BOX AUTO

When the temperature in the control box reaches 120°F ± 3°F (48.9°C

COOL DOWN

± 1.7°C), the cooling fan thermostat will switch power to the control

 

box cooling fan. The thermostat will interrupt power to the cooling fan

 

when the control box temperature falls to 100°F ± 3°F (37°C ± 1.7°C).

MAIN FAN CIRCUIT

Electrical power is permanently supplied through three 50 A fuses to

 

the normally open contacts of the hi-limit contactor. Power is also

 

supplied, through the 10 Amp motor and control fuse, through the

 

normally closed control box hi-limit thermostat, to the normally open

 

oven power switch. Power is also supplied to the control box cooling

 

fan thermostat. Closing the oven power switch supplies line voltage to

 

the main fan motor. Closing the oven power switch also supplies line

 

voltage to the heat circuit and to the primary of the oven control

 

transformer.

 

HEAT CIRCUIT

Closing the oven power switch supplies line voltage through the main

 

fan air pressure switch, through the normally closed oven cavity hi-limit

 

thermostat, to the oven control

 

TEMPERATURE CONTROL

Closing the oven power switch supplies line voltage, through the EMI

 

filter, to the primary of the control transformer and through the air

 

pressure switch and oven cavity hi-limit, to the oven control.

 

Secondary voltage, 24VAC, is supplied to the oven control. The oven

 

control is set to desired temperature. The thermocouple will provide

 

varying millivolts to the oven control. The oven control supplies line

 

voltage to the heat contactor at intermittent intervals to maintain

 

desired temperature. The display on the oven control will indicate

 

when the heat contactor is energized.

 

 

NOTE: The display also indicates oven temperature.

CONVEYOR DRIVE

Closing the oven power switch supplies line voltage to the conveyor

 

motor and to the primary of the control transformer. Secondary

 

voltage, 24VAC, is supplied to the oven control. Setting the oven

 

control to the desired time outputs voltage, through a reversing switch,

 

to the conveyor motor.

 

 

NOTE: The conveyor system uses a hall effect sensor and magnet to

 

prove operation of the conveyor motor. If the motor is not running,

 

“BELT JAM” is indicated on the display.

2

Impinger I -–Adv Digital – Electric Service Manual - International

Page 2
Image 2
Lincoln 1454, 1455 Phase, Power Supply, Control BOX Auto, Cool Down, Main FAN Circuit, Heat Circuit, Temperature Control