3. I/O DATA

 

(1)

Input Data

NMEA0183(Ver.1.5/2.0), current loop

 

 

RMA: L/L, ground track speed, advance course

 

 

RMB: Waypoint bearing/distance, cross track error

 

 

RMC: L/L(GPS), ground track speed, advance course

 

 

BWC: Waypoint bearing/distance

 

 

BWR: Waypoint bearing/distance

 

 

GLL: L/L

 

 

VTG: Ground track speed, advance course

 

 

VHW: Water track speed, advance course

 

 

MTW: Water temperature

 

 

XTE: Cross track error

(2)

Output Data

NMEA0183(Ver.1.5/2.0), RS-422, output period: 2 sec.

 

 

SDDBT(Ver1.5): Depth (ft, m, fa)

 

 

SDDPT(Ver2.0): Depth (m)

 

 

YCMTW*: Water temperature

 

 

VWVHW*: Water track speed

 

 

*: Speed/temperature sensor is required.

4. POWER SUPPLY

 

(1)

Voltage and Current

12 - 24 VDC: 1.5 - 0.5 A

5. DIMENSIONS AND MASS

 

 

 

See Outline Drawing

6. ENVIRONMENTAL CONDITION

(1)

Temperature

-15 °C to +55 °C

(2)

Relative Humidity

95% or less at 40 °C

(3)

Waterproofing

IEC IPX5

(4)

Category of Equipment Units

 

Display Unit:

To be installed in a protected area

7. COATING COLOR

 

(1)

Display Unit

Panel: N3.0 Newtone No.5

 

 

Chassis: 2.5GY5/1.5

SP - 2

Page 33
Image 33
Furuno FCV-582L manual Power Supply