A-1

INSTALLATION

A-1

Weight
Including Machine
Torch Cable (Length)
(25ft/7.6m) (50ft/15.2m)
70 lbs. 85 lbs.
32 kg. 39 kg.
INPUT - SINGLE or THREE PHASE / 60 HERTZ ONLYRATED OUTPUTOUTPUTRECOMMEND INPUT WIRE AND FUSE SIZESREQUIRED GAS FLOW RATE REQUIRED GAS INLET PRESSUREPHYSICAL DIMENSIONSTECHNICAL SPECIFICATIONS - PRO-CUT 55
Standard Voltage
Duty Cycle
50% Duty Cycle
100% Duty Cycle
Current
Range
25-55 Amps
AC Input
Voltage at
60 Hertz
1Ø - 230
1Ø - 460
3Ø - 230
3Ø - 460
Fuse
(Super Lag)
Circuit Breaker
(Delay Type)
70 AMPS
40 AMPS
40 AMPS
20 AMPS
#8 (8.4mm2)
#8 (8.4mm2)
#10 (5.3mm2)
#10 (5.3mm2)
Input Supply Wire Ground Wire
#10 (5.3mm2)
#10 (5.3mm2)
#10 (5.3mm2)
#10 (5.3mm2)
Type 75oC
Copper Wire in Conduit AWG (IEC) Sizes
Depth
26.0 in.
660 mm
Width
11.0 in.
280 mm
Height
12.6 in.
320 mm
Open Circuit
Voltage
MAX
335 VDC
For all plasma cutting applications
Based on U.S. National Electrical Code
Ambient Temperature 30oC or Less
Pilot Current
18 Amps @ 100% Duty Cycle
AMPS
55
40
1Ø Input Current at Rated Output 3Ø Input Current at Rated Output
230/460/1 or 3Ø/60 Hz 230V: 55A@ 50%, 40A @ 100%
460V: 30A@ 50%, 23A @ 100%
Idle Current: 0.42 Amps, Idle Power 98 Watts
@ 230V
230V: 28A@ 50%, 21A @ 100%
460V: 17A@ 50%, 15A @ 100%
70 PSI @ 360 SCFH
( 4.8 Bar. @ 10160 LHR)
80 to 150 PSI
( 5.4 Bar. TO 10.2 Bar.)