Lincoln Electric 4.1, 3.1 manual Welding Sparks can cause fire or explosion, Iii

Models: 3.1 4.1

1 20
Download 20 pages 63.58 Kb
Page 4
Image 4

iii

SAFETY

iii

WELDING SPARKS can cause fire or explosion.

6.a. Remove fire hazards from the welding area. If this is not possible, cover them to prevent the welding sparks from starting a fire. Remember that welding sparks and hot

materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available.

6.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1) and the operating information for the equipment being used.

6.c. When not welding, make certain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.

6.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even though they have been “cleaned”. For information, purchase “Recommended Safe Practices for the Preparation for Welding and Cutting of Containers and Piping That Have Held Hazardous Substances”, AWS F4.1 from the American Welding Society (see address above).

6.e. Vent hollow castings or containers before heating, cutting or welding. They may explode.

6.f. Sparks and spatter are thrown from the welding arc. Wear oil free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places. Always wear safety glasses with side shields when in a welding area.

6.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area increase the possibility of the welding current passing through lifting chains, crane cables or other alternate cir- cuits. This can create fire hazards or overheat lifting chains or cables until they fail.

6.h. Also see item 1.c.

CYLINDER may explode if damaged.

7.a. Use only compressed gas cylinders

containing the correct shielding gas for the process used and properly operating regulators designed for the gas and

pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.

7.b. Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.

7.c. Cylinders should be located:

Away from areas where they may be struck or subjected to physical damage.

A safe distance from arc welding or cutting operations and any other source of heat, sparks, or flame.

7.d. Never allow the electrode, electrode holder or any other electrically “hot” parts to touch a cylinder.

7.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.

7.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.

7.g. Read and follow the instructions on compressed gas cylinders, associated equipment, and CGA publication P-l, “Precautions for Safe Handling of Compressed Gases in Cylinders,” available from the Compressed Gas Association 1235 Jefferson Davis Highway, Arlington, VA 22202.

FOR ELECTRICALLY powered equipment.

8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.

8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.

8.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturer’s recommendations.

Mar ‘95

Page 4
Image 4
Lincoln Electric 4.1, 3.1 manual Welding Sparks can cause fire or explosion, Iii

3.1, 4.1 specifications

Lincoln Electric 4.1 and 3.1 represent advanced welding technologies designed to enhance the efficiency and quality of welding processes. As a leader in the welding industry, Lincoln Electric has equipped these systems with features that cater to the needs of both professional welders and industrial applications.

One of the standout characteristics of the Lincoln Electric 4.1 and 3.1 is their user-friendly interface. Both systems include intuitive controls that allow welders to easily adjust settings for optimal welding performance. This ensures that even those with varying levels of experience can achieve high-quality welds with minimal training. The digital displays provide real-time feedback, allowing users to make immediate adjustments based on the welding conditions.

In terms of performance, both models are powered by advanced inverter technology. This enables them to deliver consistent welding arcs and reduce energy consumption compared to traditional welding machines. The inverter design also contributes to a lightweight and compact frame, making it easier for welders to transport the units to different job sites or maneuver them in tight spaces.

The welding processes supported by Lincoln Electric 4.1 and 3.1 include MIG, TIG, and Stick welding, making them versatile tools suitable for a variety of applications. This adaptability is particularly beneficial for businesses that require multi-process capabilities without investing in multiple machines. The machines are equipped with features like advanced arc control and adjustable inductance, which help to refine the quality of the weld and improve the overall aesthetic finish.

Both models also prioritize safety with features such as overload protection and thermal shutdown capabilities. This ensures that the units operate within safe parameters, reducing the risk of damage to the machine and enhancing the safety of the user.

Another significant aspect of the Lincoln Electric 4.1 and 3.1 is their durability. Constructed from high-quality materials designed to withstand rigorous working conditions, these systems are built to last. The robust design means less downtime due to repairs or replacements, ultimately contributing to cost efficiency for businesses.

In summary, the Lincoln Electric 4.1 and 3.1 welding systems stand out due to their advanced technology, user-friendly interfaces, versatility in welding processes, and durable construction. These features come together to make them reliable choices for professionals seeking to enhance their welding operations while maintaining high standards of quality and efficiency.