D1.8 Seismic Supplement Welding Manual

Differences between FEMA 353 and AWS D1.8

As was previously mentioned, much of D1.8 was based upon recommendations contained within FEMA 353. However, differences between the two documents exist. In many cases, FEMA 353 recommendations are not contained in D1.8, but rather reside in the applicable AISC specification. In some situations, the AWS consensus committee made deliberate decisions to approach the issue in a different manner.

Contained below is a partial listing of some of the significant differences:

The complicated and complex “weld categories” as contained in FEMA 353 have been replaced with the three broader and simpler categories as outlined previously in Table 1.

Details of the WPS Heat Input Envelope Testing have been modified. In D1.8, the root pass can be made in a single pass (versus a split pass, as required in FEMA 353), and the position of welding is no longer an essential variable for this test. See D1.8, Annex A.

The Supplemental Welder Qualification test was expanded to include a testing procedure to address welder qualification when steel backing is not used, including where copper or ceramic backing is used, as well as when open root joints are used. See D1.8, Annex D.

Testing of the Supplemental Welder Qualification for Restricted Access Welding may be accomplished by either radiographic testing (RT), ultrasonic testing (UT) or by mechanical testing (FEMA 353 permitted only mechanical testing or RT). Additionally, the typographical error as contained in FEMA 353 that called for 3/4 in. bend tests has been corrected in D1.8 to call for the intended 3/8 in. thick bend specimens. See D1.8, Annex D.

D1.8 contains more definitive alternatives to lot tested filler metals. See D1.8, clause 6.3.8.

D1.8 specifically exempts the high/low heat envelope testing for the welding consumables when SMAW is used with specific filler metals, and when GMAW is performed with solid electrodes. See D1.8, clause 6.3.5.

D1.8 has extended the standard exposure period for FCAW electrodes from 24 to 72 hours. See D1.8, clause 6.4.3.

A variety of other changes have been made, and a careful review of the two documents must be made if the user is interested in a comprehensive comparison.