OPERATION | ||
|
|
|
GTAW
This weld mode is a constant current (CC) mode featuring con- tinuous control from 10 – 500 amps. It is intended for the GTAW TIG welding processes.
hot Start - The Hot Start control regulates the starting current at arc initiation. Hot Start can be set to “Off” and no additional current is added at arc start. When set to the “On” position, additional current (relative to the preset current) at arc initiation.
Arc Control – This control is not used in the GTAW mode.
Weld Terminals On/Remote
•When set to the “ON” position, the weld terminals are at OCV (open circuit voltage) and ready to weld.
•When set to the “REMOTE” position, output is enabled through a remote trigger.
Voltage Display Meter – This display will display three dashed lines when the machine is in the idle state. This indicates that voltage is not settable in this weld mode. While output is enabled, the actual welding voltage is displayed. After welding, the meter holds the actual voltage value for 5 seconds. Output adjustment while in the "hold" period results in the "prior to operation" characteristics. The displays blink indicating that the machine is in the "hold" period.
Amperage Display Meter – This display will display the
Output Control Local/Remote – When the control is set to local (no remote potentiometer/control plugged into the
•When a remote potentiometer is connected, the output control on the FX450 and the remote act as a master/slave configura- tion. Use the control dial on the FX450 to
Output Control Dial
•When the Local/Remote is set to Local, this dial sets the welding amperage.
•When the Local/Remote is set to Remote, this dial sets the maximum welding amperage.
The remote potentiometer controls the amperage from minimum to this
CV-GAS
This weld mode is a constant voltage (CV) mode featuring con- tinuous control from 10 to 45 volts.
It is intended for the GMAW,
hot Start – Toggle to “ON” position to provide more energy during the start of a weld.
Arc Control – The Arc Control regulates pinch effect (Inductance). At the minimum setting
Weld Terminals On/Remote
•When set to the “ON” position, the weld terminals are at OCV (open circuit voltage) and ready to weld. This selection is used for across the arc wire feeders.
•When set to the “REMOTE” position, output is enabled through a remote trigger.
Amperage Display Meter – This display will display three dashed lines when the machine is in the idle state. This indi- cates that amperage is not settable in this weld mode. While output is enabled, the actual welding amperage is displayed. After welding, the meter holds the actual amperage value for 5 seconds. Output adjustment while in the "hold" period results in the "prior to operation" characteristics. The displays blink indi- cating that the machine is in the "hold" period.
Voltage Display Meter – This display will display the
Output Control Local/Remote – When the control is set to local (no remote potentiometer/control plugged into the
Output Control Dial
•When the Local/Remote is set to Local, this dial sets the welding voltage.
•When the Local/Remote is set to Remote, this dial is disabled.