| INSTALLATION |
|
|
|
|
|
|
| ||||||
| TEChNICAL SPECIFICATIONS - FX450 |
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| POWER |
|
|
|
| ||||||||||
| Model |
|
|
| Duty Cycle | Input Voltage ± 10% | Input Amperes |
| Idle Power |
| Power Factor @ |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Rated Output |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| 60% rating |
|
| 37 / 27 / 22 |
|
| 72 Watts |
|
|
| ||||||
|
|
|
|
|
|
| 380 / 460 / 575 / 3 / 50 / 60 |
|
|
|
|
|
| Max. |
|
| 95% |
| |||
|
|
|
| 100% rating |
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
| 29 / 21 / 17 |
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
| (fan on) |
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RATED OuTPuT |
|
|
|
|
|
|
|
|
| ||
| Process |
|
|
| Duty Cycle | Volts at Rated Amperes |
|
|
|
| Amperes |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 60% |
|
| 36.5V |
|
|
|
|
|
|
| 450 |
|
|
| |
| GMAW (CV) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| 100% |
|
| 34V |
|
|
|
|
|
|
| 400 |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 60% |
|
| 28V |
|
|
|
|
|
|
| 450 |
|
|
| |
| GTAW (CC) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| 100% |
|
| 26V |
|
|
|
|
|
|
| 400 |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 60% |
|
| 38V |
|
|
|
|
|
|
| 450 |
|
|
| |
| SMAW (CC) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| 100% |
|
| 36V |
|
|
|
|
|
|
| 400 |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 60% |
|
| 36.5V |
|
|
|
|
|
|
| 450 |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
| 100% |
|
| 34V |
|
|
|
|
|
|
| 400 |
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 60% |
|
| 36.5V |
|
|
|
|
|
|
| 450 |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| 100% |
|
| 34V |
|
|
|
|
|
|
| 400 |
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| RECOMMENDED INPuT WIRE AND FuSE SIzES (1) |
|
|
|
| ||||||||||
| VOLTAGE | Maximum |
| Cord Size(3) | Type 75°C Copper | COPPER GROuNDING | Fuse (Super Lag) or |
| |||||||||||||
| 50/60hz |
| Input |
| AWG SIzES | Wire in Conduit |
| CONDuCTOR |
| Breaker Size (2) |
| ||||||||||
|
| Amperes |
|
| (mm) | AWG (mm2) |
|
| AWG (mm2) |
|
|
|
| ||||||||
| 380/3/50 |
| 42 A |
|
| 8(10) | 8 (10) |
|
|
|
| 10 (6) |
|
| 50 |
| |||||
| 460/3/60 |
| 30 A |
|
| 8(10) | 10 (6) |
|
|
|
| 10 (6) |
|
| 45 |
| |||||
| 575/3/60 |
| 25 A |
|
| 10(6) | 12 (4) |
|
|
|
| 12 (4) |
|
| 35 |
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(1)Cord and Fuse Sizes based upon the U.S. National Electric Code and maximum output for 40°C (104°) ambient.
(2)Also called “inverse time” or “thermal/magnetic” circuit breakers; circuit breakers that have a delay in tripping action that decreases as the magnitude of current increases.
(3)Type SD cord or similar in 30°C ambient.