b-15

OPERATION

b-15

POWER WAVE® C300

ALuMINuM GMAW-P (PuLSED MIG)

AND GMAW-PP (PuLSE ON PuLSE)

WELDING

START OPTIONS
END OPTIONS
SETUP
WELD MODE
UltimArc™ Control
Less
Deposition
More
Deposition
Shorter
Arc
Longer
Arc
++
AMPS
WFSVOLTS
TRIM
2201.06
72
EFFECT / RANGE
PULSE
PULSE-ON-PULSE
FREQUENCY:
FREQ.MODULATION
(Low)-10.0 to
(High)+10.0
(Low)-10.0 to
(High)+10.0
DESCRIPTION
For Pulse -On-Pulse modes,
Arc controls changes the frequ-
ency modulation. The freque-
-ncy modulation controls the
spacing of the ripples in the
weld. Use low values for slow
travel speeds and wide welds,
and high values for fast travel
speeds and narrower welds.
For Pulse modes, Arc Control
changes the pulsing frequency.
When the frequency changes,
the Power Wave system auto-
matically adjusts the back-
ground current to maintain a
similar heat input into the weld.
Low frequencies give more con-
trol over the puddle and high
frequencies minimize spatter.
EFFECT
Postflow Time
RUN-INWFS:
.
Start Procedure
DESCRIPTION
Adjusts the time that shielding
gas flowsafter the trigger is
pulled
andprior to feeding wire.
Run-in sets the wire feed
speed from the time the trigger
is pulled until an arc is estab-
lished.
The Start Procedure controls
the WFS. Trim at a specified
time at the beginning of the
weld. During the start time, the
machine will ramp up or down
from the Start Procedure to the
preset Welding Procedure.
EFFECTFUNCTION
ELECTRODE AND GAS
ALUMINUM 4043
ALUMINUM 4043
ALUMINUM 5356
ALUMINUM 5356
Ar
Ar
Ar
Ar
WIRE SIZE
0.035 3/64 1/16
149 72 74
98 99 100
152 76 78
101 102 103
WELD MODES
START OPTIONS
END OPTIONS
UltimArc™ Control
Aluminum 3/64"
Pulse 4043 Ar
Spot Timer Adjust the time welding will
continue even if the trigger
is still pulled. This option
has no effect in 4-Step
Trigger Mode.
Crater ProcedureCrater Procedure controls the
WFS and Volts for a specified
time at the end of the weld
after the trigger is released.
During the Crater time, the
machine will ramp up or down
from the Weld Procedure to
the Crater Procedure.
Burnback: The burnback time is the
amount of time that the weld
output continues after the wire
stops feeding. It prevents the
wire from sticking in the puddle
and prepares the end of the
wire for the next arc start.
Postflow TimeAdjusts the time that shielding
gas flows after the welding out-
put turns off.
START OPTIONS
END OPTIONS
SETUP
WELD MODE
UltimArc™ Control
Less
Deposition
More
Deposition
Shorter
Arc
Longer
Arc
++
AMPS
WFS VOLTS
TRIM
220 1.0672
EFFECT / RANGE
PULSE
PULSE-ON-PULSE
FREQUENCY:
FREQ.MODULATION
(Low)-10.0 to
(High)+10.0
(Low)-10.0 to
(High)+10.0
DESCRIPTION
For Pulse -On- Pulse modes,
Arc controls c hanges the f requ-
ency modulation. The freque-
-ncy modulation controls the
spacing of the ripples in the
weld. Use low values for slow
travel speeds and wide welds,
and high value s for fast t ravel
speeds and narrower welds.
For Pulse modes, Arc C ontrol
changes the pulsing frequency.
When the frequency changes,
the Power Wave s ystem auto-
mati call y adj ust s the ba ck-
ground curr ent to mainta in a
similar heat input into the weld.
Low frequencies give more con-
trol over the puddle and high
frequencies minimize spatter.
EFFECT
Postflow Time
RUN-INWFS:
.
Start Procedure
DESCRIPTION
Adjusts the time that shielding
gas flowsafter the tri gger is
pulled
andprior to feeding wire.
Run- in s ets t he w ire fee d
speed from the time the trigger
is pulled until an arc is estab-
lished.
The Star t Pro cedure controls
the WFS. Trim at a spec ified
time at t he beginn ing of the
weld. During the start time, the
machine will ramp up or down
from the Start Procedure to the
preset Welding Procedure.
EFFECT FUNCTION
ELECTRODE AND GAS
ALUMINUM 4043
ALUMINUM 4043
ALUMINUM 5356
ALUMINUM 5356
Ar
Ar
Ar
Ar
WIRE SIZE
0.035 3/64 1/16
149 72 74
98 99 100
152 76 78
101 102 103
WELD MODES
START OPTIONS
END OPTIONS
UltimArc™ Control
Aluminum 3/64"
Pulse 4043 Ar
Spot Timer Adju st t he tim e we ldi ng will
cont inue ev en if t he tri gger
is s till pu lle d. T his op tion
has no e ffe ct in 4 -St ep
Trig ger Mod e.
Crater Procedure Crater Procedu re controls the
WFS and Volts for a specified
time at the end of th e w eld
after the trigg er i s re leased .
Durin g t he Crat er time , t he
machine will ramp up or down
from the Weld Pro cedure to
the Crater Procedure.
Burnback: The bu rnb ack time is the
amount o f tim e that the weld
output continues after the wire
stops feed ing. It prevents the
wire from sticking in the puddle
and pr epares the end of the
wire for the next arc start.
Postflow Time Adjusts the time that shi elding
gas flows after the welding out-
put turns off.
bASIC OPERATION