A-1

INSTALLATION

A-1

Weight
Including
Torch Cable
35 lbs.
15.9 kg.
INPUT - SINGLE PHASE / 60 HERTZ ONLYRATED OUTPUTOUTPUTRECOMMEND INPUT WIRE AND FUSE SIZESREQUIRED GAS FLOW RATE REQUIRED GAS INLET PRESSUREPHYSICAL DIMENSIONSTECHNICAL SPECIFICATIONS - PRO-CUT 25 (K1756-1)
Standard Voltage
Duty Cycle
20% on 115 V
60% on 115 V
100% on 230 V
35% on 115 V
60% on 230 V
Current
Range
12-25 Amps
AC Input
Voltage
at
50/60
Hertz
230V-1Ø
115V-1Ø
115V-1Ø
115V-1Ø
Fuse
(Super Lag)
Circuit Breaker
(Delay Type)
20 AMPS
15 AMPS
20 AMPS
30 AMPS
#14 (2.5 mm2)
#12 (4 mm2)
#12 (4 mm2)
#12 (4 mm2)
2 Input Supply Wires 1 Ground Wire
#14 (2.5 mm2)
#12 (4 mm2)
#12 (4 mm2)
#12 (4 mm2)
Type 75oC
Copper Wire in Conduit
AWG (IEC) Sizes
Depth
16.1 in.
410 mm
Width
6.3 in.
160 mm
Height
10.2 in.
260 mm
Open Circuit
Voltage
400 VDC
For all plasma cutting applications
Based on U.S. National Electrical Code
Ambient Temperature 30oC or Less
Pilot Current
12 Amps
AMPS
15 A
20 A
20 A
25 A
25 A
1Ø Input Current at Rated Output
115/230/1/50/60Hz 115 V : 15 A@ 20%
115 V : 26.7A@ 60%
115 V : 37.7A@ 35%
230 V : 15 A@100%
230 V : 19 A@ 60%
55 PSI @ 240 SCFH
( 3.8 Bar. @ 6800 LHR)
65 to 150 PSI
(4.5 Bar. TO 10.3 Bar.)
25 A
15 A
20 A
25 A
Output Input Cord
Plug
Size
6-20P or 6-30P or 6-50P
5-15P* or 5-20P* or 5-30P or 5-50P
5-20P* or 5-30P or 5-50P
5-30P or 5-50P
* Included with machine
PRO-CUT 25