A-7
INSTALLATION
POWER WAVE 455/STT
A-7FIGURE A.8
Simple System
SYSTEM SET-UP
Basic Rules
Each group is required to have one user interface.
No group may have more than one user interface.
Each group can have up to seven Feed Heads.
Exception: Group 3 is limited to a maximum of six
Feed Heads.
Each system has only one power source. For net-
work purposes, the PS belongs to Group 3, which is
why group 3 is only allowed 6 feed heads in addition
its user interface.
No two feed heads can have identical Group and
Feed Head numbers.
Group and Feed Head ID numbers must be set on
the appropriate dipswitches at each node. Consult
the PF-10/11 Instruction Manual for specific details
regarding dipswitch settings.
Feed head 0 not allowed. Exception: Simple sys-
tem ignores all ID numbers, therefore FH0 will
function.
Each node must be connected to the Linc-Net com-
munication network. The order of connection is not
important, as each node is identified by its unique
Group and Feed Head ID number as defined on its
dipswitches. See Figures A.8 thru A.12.
Group and Feed
Head ID numbers are
ignored in a simple
system.