B-2

OPERATION

B-2

 

 

 

RANGE” SWITCH

 

 

 

 

 

 

 

 

Process

Range Setting

Current Range

 

 

 

 

 

 

STICK/TIG

 

90 Max.

 

50 to 90 Amps

(constant current)

145 Max.

70 to 145 Amps

 

(3 range settings)

210 Max.

120 to 210 Amps

 

 

 

 

 

 

 

 

 

 

 

CAUTION

Never change the “RANGE” Switch setting while welding. This will damage the switch.

------------------------------------------------------------------------

CONTROL” DIAL

Provides a fine welding current adjustment within the

Range Switch settings.

EAGLE 10,000 APPROXIMATE FUEL CONSUMPTION

 

KOHLER

 

20 H.P. COMMAND

 

 

Low Idle - No Load

.39 Gallons/Hour

2200 RPM

(1.49 Liters/Hour)

 

High Idle - No Load

.74 Gallons/Hour

3700 RPM

(2.79 Liters/Hour)

 

 

AC CC Weld Output

1.22 Gallons/Hour

225 Amps @ 25 Volts

(4.63 Liters/Hour)

 

 

DC CC Weld Output

1.29 Gallons/Hour

210 Amps @ 25 Volts

(4.87 Liters/Hour)

 

 

DC CV Weld Output

1.18 Gallons/Hour

 

200 Amps @ 20 Volts

(4.48 Liters/Hour)

Auxiliary Power

1.40 Gallons/Hour)

9000 Watts

(5.31 Liters/Hour)

 

 

 

EAGLE 10,000

Page 18
Image 18
Lincoln Electric IM830 Eagle 10,000 Approximate Fuel Consumption, Range Switch, Control Dial, Kohler, 20 H.P. Command