A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS - Ranger 305D (K1727-2)

Make/Model

Kubota**

D722

 

INPUT - DIESEL ENGINE

Description

Speed (RPM)

Displacement

 

 

cu. in. (cu. cm.)

3 cylinder

 

43.88(789)

4 stroke

 

 

 

Bore x Stroke inch (mm)

18.8 HP

High Idle 3650

(14 KW)

 

 

Net intermittent

Full Load 3500

2.64 x 2.68

3600 RPM

 

(67 x 68 mm)

naturally aspirated

Low Idle 2450

 

water cooled

 

 

Diesel Engine

 

 

Starting

Capacities

System

 

12VDC Battery &

Fuel: 12 gal.

starter

(45 Liters)

 

Oil: 3.4Qts. (3.2L)

(Group 58; 550

Radiator Coolant:

cold crank amps)

3.85Qts. (3.6L)

Battery Charger

 

(3.6L)

 

 

 

RATED OUTPUT @ 104° F (40° C) - WELDER

Welding Process

Welding Output

Output Range

Max. Weld OCV

 

Current/Voltage/Duty Cycle

 

@Rated Load RPM

DC Constant Current

305A / 29V / 100%

20 TO 305 AMPS

 

DC Pipe Current

300A / 29V / 100%

40 TO 300 AMPS

 

Touch-Start™TIG

250A / 30V / 100%

20 TO 250 AMPS

60 Volts

DC Constant Voltage

300A / 29V / 100%

14 TO 29 VOLTS

 

 

 

 

 

RATED OUTPUT @ 104° F (40° C).- GENERATOR

Auxiliary Power 1

10,000 Watts Peak, / 9,500 Watts Continuous, 60 Hz 120/240 Volts

Sound Levels

Sound Power: 104.2 dB Lwa, Sound Level: 80.6 dBA @ 23 ft ( 7m )

PHYSICAL DIMENSIONS

HEIGHT

WIDTH

DEPTH

 

WEIGHT

30.00* in.

21.50 in

52.25 in.

 

 

 

 

698 lbs. (317kg.)

 

762.0 mm

546.0 mm

1327.0 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGINE

 

 

 

 

 

 

 

 

 

LUBRICATION

 

EMISSIONS

FUEL SYSTEM

 

 

GOVERNOR

Full Pressure

 

 

 

Electric Fuel Pump (Code 11121) or

 

 

Mechanical

 

with Full Flow Filter

Certified to EPA Tier I

Mechanical Fuel Pump (Code 11188, 11275), Auto air bleed

Governor

 

 

 

 

system Electric shutoff solenoid Indirect fuel injector

 

 

AIR CLEANER

 

ENGINE IDLER

MUFFLER

 

ENGINE PROTECTION

 

 

 

 

 

 

Low noise Muffler:

 

Shutdown on low oil

Single Element

 

Automatic Idler

Top outlet can be rotated.

 

pressure & engine

ENGINE WARRANTY:

 

 

 

Made from long life, aluminized steel.

 

temperature

2 year complete (parts and labor) 3rd. year major components (parts and labor)

 

 

RECEPTACLES AND CIRCUIT BREAKERS

 

 

 

 

 

 

RECEPTACLES

 

AUXILIARY POWER CIRCUIT BREAKER

OTHER CIRCUIT BREAKERS

 

 

 

(2) 120VAC GFCI Duplex (5-20R)

Two 20AMP for Two Duplex Receptacle

15AMP for Battery Charging Circuit

(1) 120/240VAC Dual Voltage

One 50AMP for Dual Voltage(2-pole)

15AMP for 42V Wire Feeder Power

Full KVA (14-50R)

 

Below code 11275 two 50AMP

Below code 11275 Battery

 

 

 

cicuit breakers were used for

Charging Circuit Breaker was

 

 

 

Dual Voltage

25 amps

 

 

 

 

 

 

 

 

 

1. Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.

* Top of enclosure add 6in. (152mm) for exhaust pipe.

** Engine warranty may vary outside of the USA. (See Engine warranty for details)

RANGER 305D

Page 9
Image 9
Lincoln Electric IM836-B Installation, Height Width Depth Weight, Lubrication Emissions Fuel System Governor, Ranger 305D