OPERATION | ||
|
|
|
WELDING PROCESS
For any electrodes the procedures should be kept within the rating of the machine. For electrode infor- mation see the appropriate Lincoln publication.
STICK (CONSTANT CURRENT) WELDING
Connect welding cables to the "TO WORK” and "ELECTRODE” studs. Start the engine. Set the "Polarity” switch to the desired polarity. The “RANGE” switch markings indicate the maximum current for that range as well as the typical electrode size for that range. The “OUTPUT” Control provides fine adjust- ment of the welding current within the select range. For maximum output within a selected range set the “OUTPUT” Control at 10. For minimum output within a selected range set the “OUTPUT” Control at 5. (“OUT- PUT” Control settings below 5 may reduce arc stabili- ty) For best overall welding performance set the “RANGE” Switch to the lowest setting and the OUT- PUT” Control near the maximum to achieve the desired welding current.
| RANGE SETTING |
| TYPICAL | CURRENT RANGE | |||
|
|
| ELECTRODE SIZE |
|
|
| |
| 90 MAX. |
|
|
|
|
|
|
| 3/32 |
| |||||
|
|
| 50 TO 90 AMPS | ||||
|
|
|
|
|
|
|
|
| 125 MAX. |
| 1/8 |
|
| 70 TO 145 AMPS |
|
|
|
|
|
|
|
|
|
| 210(DC)/225(AC) |
| 5/32 |
|
| 120 TO 210(DC), |
|
| MAX. |
|
|
|
| 225(AC) AMPS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
The RANGER 3 PHASE can be used with a broad range of AC and DC stick electrodes. See “Welding Tips 1” included with the RANGER 3 PHASE for elec- trodes within the rating of this unit and recommended welding currents of each.
TIG (CONSTANT CURRENT) WELDING
The
When using the RANGER 3 PHASE for AC TIG weld- ing of aluminum, the following settings and electrodes are recommended:
SETTINGS FOR PURE TUNGSTEN
TUNGSTEN | RANGE SWITCH | APPROXIMATE | |||||
DIAMETER (in.) | SETTINGS | CURRENT RANGE | |||||
|
|
|
|
|
|
|
|
1/8 | 90 | or | 145 | 80 | - | 150 | Amps |
3/32 | 90 | or | 145 | 45 | - | 130 | Amps |
1/16 |
| 90 |
| 40 - 80 Amps | |||
|
|
|
|
|
|
|
|
SETTINGS FOR 1% THORIATED TUNGSTEN
TUNGSTEN | RANGE SWITCH | APPROXIMATE | |||
DIAMETER (in.) | SETTINGS | CURRENT RANGE | |||
|
|
|
|
| |
1/8 | 90, 145, or 210 | 80 | - 225 | Amps | |
3/32 | 90 or 145 | 50 | - | 180 | Amps |
1/16 | 90 or 145 | 45 | - | 120 | Amps |
|
|
|
|
|
|
The
WIRE FEED WELDING PROCESSES (CONSTANT VOLTAGE)
The Innershield® electrode recommended for use with the RANGER 3 PHASE is
Diameter | Wire Speed | Approximate | |
(in.) | Range In./Min. | Current Range | |
|
|
|
|
.035 | 80 | - 110 | 75A to 120A |
.045 | 70 | - 130 | 120A to 170A |
.068 | 40 | - 90 | 125A to 210A |
|
|
|
|
The RANGER 3 PHASE is recommended for limited “MIG” welding (GMAW - gas metal arc welding). The recommended electrodes are.030” and .035”SuperArc
Diameter | Wire Speed | Approximate |
(in.) | Range In./Min. | Current Range |
|
|
|
.030 | 80 - 110 | 75A to 120A |
.035 | 70 - 130 | 120A to 170A |
|
|
|
ARC GOUGING
The RANGER 3 PHASE can be used for limited arc gouging.
Set the Range switch to adjust output current to the desired level for the gouging electrode being used according to the ratings in the following table:
CARBON DIAMETER (in) | CURRENT RANGE (DC, electrode positive) | ||
|
|
|
|
1/8 | 30 | - | 60 Amps |
5/32 | 90 | - | 150 Amps |
3/16 | 200 - 250 Amps | ||
|
|
|
|