E-1

 

TROUBLESHOOTING

 

E-1

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

 

 

PROBLEMS

POSSIBLE CAUSE

REMEDY

 

(SYMPTOMS)

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

 

 

 

 

 

 

Drive rolls turn, but wire will not

a. Gun cable kinked and/or twisted.

a. Keep as straight as possible.

feed or wire feeding is rough.

 

Inspect cable and replace if

 

 

 

necessary.

 

 

b. Wire jammed in gun and cable.

b. Remove wire from gun and cable

 

 

 

– feed in new wire. Note any

 

 

 

obstruction. Replace liner if

 

 

 

necessary.

 

 

c. Incorrect drive rolls and guide

c. Be sure the wire diameter being

 

 

tubes.

used is stamped on drive rolls

 

 

 

and guide tubes. Replace if

 

 

 

necessary.

 

 

d. Gun cable liner dirty.

d. Clean liner or replace.

 

 

e. Worn drive rolls.

e. Replace or reverse split drive roll

 

 

 

type.

 

 

f. Electrode rusty and/or dirty.

f. Replace the electrode if it is

 

 

 

rusty.

 

 

g. Worn or improper size cable liner.

g. Replace cable liner.

 

 

h. Partially flashed, melted or

h. Replace the contact tip.

 

 

improper size contact tip.

 

 

 

 

 

 

 

Variable or “hunting” arc.

a. Contact tip worn or incorrect size.

a. Replace contact tip.

 

 

b. Worn or undersize work cables or

b. Inspect – repair or replace as

 

 

poor ground connections.

necessary.

 

 

c. Loose electrode connections.

c. Be sure the following connections

 

 

 

are tight: electrode cable to wire

 

 

 

feeder and power source, work

 

 

 

cable to power source and work,

 

 

 

gun cable to wire feeder contact

 

 

 

block, gun nozzle to body and

 

 

 

contact tip to nozzle.

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

MAGNUM 300 & 400

Page 23
Image 23
Lincoln Electric K2286-1, K471, K470, K514, K1802-1 manual Troubleshooting, Problems