Date: | 3/7/2008 | MSDS No.: |
Trade Name: | Innershield | |
Sizes: | All |
|
Supersedes: | 3/29/00 |
|
M A T E R I A L S A F E T Y D A T A S H E E T
For Welding Consumables and Related Products
Conforms to Hazard Communication Standard 29CFR 1910.1200 Rev. October 1988
SECTION I - IDENTIFICATION
| Manufacturer/ | The Lincoln Electric Company | Product Type: | Flux Cored Electrode |
| Supplier: |
|
| |
| 22801 St. Clair Avenue |
|
| |
|
| Cleveland, OH |
|
|
|
| Classification: | AWS | |
|
| (216) |
|
|
|
|
|
| |
|
| SECTION II - HAZARDOUS MATERIAL (1) |
I M P O R T A N T !
This section covers the materials from which this product is manufactured. The fumes and gases produced during welding with the normal use of this product are covered by Section V; see it for industrial hygiene information.
CAS Number shown is representative for the ingredients listed. All ingredients listed may not be present in all sizes.
(1) The term “hazardous” in “Hazardous Materials” should be interpreted as a term required and defined in the Hazards Communication Standard and does not necessarily imply the existence of any hazard. All materials are listed on the TSCA inventory.
|
|
| TLV | PEL |
Ingredients: | CAS No. | Wt.% | mg/m3 | mg/m3 |
Barium compounds (as Ba)***** | 5 | **** | **** | |
Fluorides (as F) | < 5 | 2.5 | 2.5 | |
Iron oxides | < 5 | 5 | 10 | |
Aluminum and/or aluminum alloys (as Al)***** | < 5 | 10 | 15 | |
Magnesium and/or magnesium alloys and compounds (as Mg) | < 5 | 10* | 10* | |
Manganese and/or manganese alloys and compounds (as Mn)***** | 1 | 0.2 | 5 (c) | |
Nickel (metal)***** | 1 | 1.5 | 1 | |
Lithium compounds (as Li) | 0.5 | 10* | 10* | |
Mineral silicates | 0.5 | 5** | 5** | |
Limestone and/or calcium carbonate | < 0.5 | 10 | 15 | |
Zirconium alloys and compounds (as Zr) | < 0.5 | 5 | 5 | |
Silicon and/or silicon alloys and compounds (as Si) | < 0.5 | 10* | 10* | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Carbon steel tube | 80 | 10* | 10* |
Supplemental Information:
(*) | Not listed. Nuisance value maximum is 10 milligrams per cubic meter. (*****) | Subject to the reporting requirements of Sections |
| PEL value for iron oxide is 10 milligrams per cubic meter. TLV value | 311, 312, and 313 of the Emergency Planning and |
| for iron oxide is 5 milligrams per cubic meter. | Community |
(**) | As respirable dust. | 40CFR 370 and 372. |
| ||
(****) | (c) | Value is for manganese fume. Present PEL is 5 |
There is no listed value for insoluble barium compounds. The TLV | milligrams per cubic meter (ceiling value). Values | |
| for soluble barium compounds is 0.5 mg/m3. | proposed by OSHA in 1989 were 1.0 milligrams per |
|
| cubic meter TWA and 3.0 milligrams per cubic meter |
|
| STEL (Short Term Exposure Limit). |
SECTION III - HAZARD DATA
Non Flammable; Welding arc and sparks can ignite combustibles and flammable products. See Z49.1 referenced in Section VI. Product is inert, no special handling or spill procedures required. Not regulated by DOT.
Rev 9/07 | (CONTINUED ON SIDE TWO) |