Linear DXS-80 specifications Wireless Carbon Monoxide Alarm, Specifications

Models: DXS-80

1 2
Download 2 pages 9.54 Kb
Page 1
Image 1
DXS-80

DXS-80

Wireless Carbon Monoxide

Alarm

The DXS-80 is a UL listed, single station, carbon monoxide alarm with a built-in supervised transmitter. It is compatible with Linear’s wireless DXS Format Security Systems, Personal Emergency Reporting Systems (PERS), and other stand-alone receivers. The DXS-80 provides a warning to alert against both the acute and chronic effects of carbon monoxide (CO) poisoning.

When carbon monoxide is detected, the alarm sounds a loud local alarm. The built-in transmitter sends a digitally coded wireless signal to its companion receiver every 20 seconds until the air has cleared and the detector is restored.

The local alarm can be silenced once by pressing the test/ reset button. The transmitter will continue to send an alarm signal every 20 seconds. After 7 minutes, the alarm will sound again if there is still an unsafe carbon monoxide concentration level. The reset function can be used only once for each alarm occurrence.

No field coding is required because the DXS-80 is factory set to a unique code; one of over a million possible codes.

The DXS-80 is powered by one 3-volt lithium battery.The battery is supplied and can power the unit for up to the six year life of the detector. If the battery voltage drops below a preset level the alarm will sound a low battery chirp every 45 seconds and a low battery signal will be sent to the receiver.

At about 6 years,the carbon monoxide detector element will reach the end of its serviceable life.The self-supervising detector will signal a permanent trouble condition, indicating time for replacement.

SPECIFICATIONS

REGULATORY LISTINGS:

UL2034

 

 

 

DETECTION METHODS:

Electrochemical

 

 

 

TIME TO ALARM PER UL 2034:

 

 

 

 

 

 

Carbon Monoxide

Minimum Time

Maximum Time

 

 

Concentration Level

to Alarm

to Alarm

 

 

50 ppm +/-5 ppm

30 days

Indefinite

 

 

70 ppm +/-5 ppm

60 min

240 min

 

 

150 ppm +/-5 ppm

10 min

50 min

 

 

400 ppm +/-5 ppm

4 min

15 min

 

 

AUDIBLE OUTPUT:

85 dBA/10'

 

 

OPERATING TEMP. RANGE:

32º-100º F

 

 

 

POWER:

3-Volt battery (Lithium Type 123A)

 

 

(UL tested for greater than 1 year service life)

 

CURRENT:

7 mA alarm average, 15 µA standby

 

FREQUENCY:

315 MHz

 

 

 

NUMBER OF CODES:

One of 1,048,576 possible codes

 

DIMENSIONS:

5.3" diameter, 2.0"h

Model DXS-80

(SST00116)

Carbon Monoxide Alarm

Also available as a kit:

DX-COKIT

(SSA00020)

Kit contains one DXR-702 receiver with a DXS-80 already learned into the receiver

NOTE: The DX-COKIT is not for use

in UL Listed applications

Model DXR-702

(SNR00149)

2-Channel Receiver

COMPATIBLE RECEIVERS: PERS-3600

PERS-2400A

DXSR-1504

DXSR-1508

DVS-1200

DXR-702

DUAL-824

DVS-2400

The DXS-80 is currently UL Listed for use with the Linear PERS Consoles only. It has not been tested by UL with other compatible Linear receivers.