Linear DXS-80 installation instructions Signaling, Carbon, Alarm, Wireless, Monoxide, Listed

Models: DXS-80

1 2
Download 2 pages 48.89 Kb
Page 1
Image 1
DXS-80

DXS-80

 

 

PRODUCT DESCRIPTION

 

DXS-80 FEATURES

 

 

The DXS-80 is a carbon monoxide (CO) alarm with a built-in transmitter

 

 

 

CARBON

MOUNTING

 

 

designed for use with Linear’s DXS and DX Format receivers. The

ALARM

 

 

 

 

 

 

detector gives warning to alert against both the acute and chronic

SOUNDER

 

 

MONOXIDE

PLATE

 

 

 

BY

effects of CO poisoning. When carbon monoxide is detected, the alarm

 

 

 

ALARM

 

 

 

 

 

 

 

 

 

WIRELESS

 

 

sounds a loud local alarm. When the local alarm sounds, the built-in

 

 

 

 

 

 

 

transmitter sends a digitally coded wireless signal to its companion

 

 

 

 

 

CARBON

 

 

receiver every 20 seconds until the air has cleared and the detector

 

 

 

 

 

 

 

is restored.

 

 

 

 

 

MONOXIDE

 

 

The local alarm can be silenced once by pressing the TEST/RESET

 

 

 

 

 

 

 

button. The transmitter will continue to send an alarm signal every 20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM

 

 

seconds. After 7 minutes, the alarm will sound again if there is still an

TEST/RESET

MOUNTING

 

 

 

unsafe CO concentration level. The reset function can be used only

SCREWS &

 

 

 

BUTTON

 

 

 

 

 

 

once for each alarm occurrence.

 

ANCHORS

 

 

 

 

 

 

 

 

 

 

 

 

 

The DXS transmitters are precoded at the factory to one of over a

 

 

 

ALARM SIGNALS

 

 

 

 

million possible unique system codes, so no field coding is required.

 

 

 

 

 

 

 

NORMAL

 

 

 

 

 

 

 

 

Receivers must be programmed to the transmitter’s code before

GREEN LED FLASHES EVERY 10 SECONDS.

Installation

 

 

OPERATION

 

SIGNALING

system testing and operation. Refer to the receiver’s instructions for

 

A REPEATING PATTERN OF FOUR SHORT BEEPS AND

Instructions

 

details on programming.

ALARM

5 SECOND SILENCE. THE RED LED WILL FLASH ONCE

 

 

The unit is powered by one 3-volt lithium battery.The battery is supplied

SIGNAL

PER SECOND.

 

 

 

 

 

with the transmitter and can power the unit for more than one year. If the

 

DETECTOR SELF-TESTS EVERY 5 SECONDS. IF A FAULT

 

 

 

 

battery voltage drops below a preset level the alarm will sound a low

 

 

 

 

®

TROUBLE IS DETECTED, RED LED WILL BLINK ONCE EVERY

 

 

 

 

battery chirp every 45 seconds and a low battery signal will be sent to

 

 

 

LISTED

SIGNAL 5 SECONDS AND DETECTOR WILL BEEP EVERY 45

 

 

 

the receiver (some receivers can report low battery, others cannot).

 

 

 

 

SECONDS.

 

 

 

 

 

When the detector reaches the end of its serviceable life (after about 6

LOW BATTERY RED LED BLINKS EVERY 45 SECONDS.

 

 

 

 

years) a permanent trouble condition will occur and cannot be reset.

 

 

 

 

SIGNAL

REPLACE THE BATTERY WHEN THIS SIGNAL OCCURS.

 

 

 

 

Maintenance: Occasionally clean the outside casing with a cloth.

 

RED LED WILL BLINK ONCE EVERY 10 SECONDS AND

 

 

 

 

Ensure that the holes on the front of the alarm are not blocked with dirt

 

 

 

 

 

END-OF-LIFEDETECTOR WILL BEEP EVERY 45 SECONDS. IN THIS

 

USA & Canada (800) 421-1587 & (800) 392-0123

and dust. Do not paint, and do not use cleaning agents, bleach, or

SIGNAL

CONDITION,THE DETECTOR REQUIRES IMMEDIATE

 

(760) 438-7000 - Toll Free FAX (800) 468-1340

polish on the detector.

 

REPLACEMENT.

 

 

 

www.linearcorp.com

 

 

 

 

 

 

 

SELECT PROPER LOCATIONREMOVE MOUNTING PLATE

 

REMOVE BATTERY TAB

REFER TO SECTION

 

Kitchen Dining Bedroom

 

 

 

NOTE: ON POWER-UP THE RED AND

NUMBER 5 ON THE

 

Room

 

 

 

Family Room

 

TWIST MOUNTING

 

 

GREEN LEDS WILL BLINK 4 TIMES,

REAR OF THESE

 

 

 

 

Living Room

 

 

15 SECONDS APART WHILE

INSTRUCTIONS FOR

 

PLATE TO UNLOCK

REMOVE

 

 

Bedroom

 

THE ALARM INITIALIZES.

IMPORTANT MOUNTING

 

 

 

BATTERY TAB

 

 

 

 

 

 

DETAILS

 

= Carbon Monoxide

 

 

 

 

 

 

TO APPLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bedroom

alarm location

 

POWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE 1. RECOMMENDED

 

 

 

 

 

 

 

 

 

CO ALARM PLACEMENT FOR

 

 

 

 

 

 

 

 

 

SINGLE FLOOR RESIDENCE

 

 

CONNECT BATTERIE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S

 

 

Bedroom

 

 

 

 

 

 

 

 

Bedroom

Bedroom

 

FIGURE 2. RECOMMENDED

 

 

TO

 

 

 

 

 

 

 

 

PULL

 

 

 

Living

Kitchen

 

CO ALARM PLACEMENT FOR

 

 

 

 

 

Garage

 

 

 

 

 

 

 

MULTI-LEVEL RESIDENCE

 

 

 

 

 

 

Room

 

 

 

 

 

 

 

Basement

= Carbon Monoxide alarm

 

 

 

 

 

 

 

 

location for multi-level

 

 

 

 

 

 

 

 

residence

 

 

 

 

 

 

 

 

 

Inside wall location

 

 

 

 

 

 

FIGURE 3. RECOMMENDED

 

REMOVE

 

 

 

 

 

 

MOUNTING

3-VOLT LITHIUM BATTERY - TYPES: DURACELL DL123A,

CO ALARM MOUNTING

Height 5' - 6' from floor

LOCATION IS 5 TO 6 FEET

 

PLATE

PANASONIC CR123A, SANYO CR123A, ADEMCO 466.

FROM FLOOR

 

 

 

AVAILABLE AT LOCAL RETAILERS AND INTERNET

 

 

 

 

 

SUPPLIERS. NOTE: USE ONLY THESE SPECIFIC

 

 

 

= Carbon Monoxide alarm

 

BATTERY MODELS.

 

 

 

 

mounting location

 

 

 

 

 

 

 

INSTALL MOUNTING PLATEPROGRAM RECEIVERMOUNT ALARM ON PLATE

 

 

SCREW

REFER TO RECEIVER'S INSTRUCTIONS TO

TWIST CO ALARM CLOCKWISE TO

 

 

PREPARE RECEIVER TO ACCEPT THE

LOCK ONTO MOUNTING PLATE

 

 

ANCHORS

 

 

TRANSMITTER'S CODE

 

 

 

 

 

 

 

FOR WALLBOARD

 

 

 

 

 

 

 

 

 

 

 

 

 

PRESS UNTIL ALARM

BEEPS THEN RELEASE

TEST BUTTON TO

SEND SIGNAL

OR

 

A TEST SIGNAL WILL BE SENT A

ALIGN TAB IN PLATE WITH

PLASTIC

FEW SECONDS AFTER THE

NOTCH IN COVER

SWITCH IS RELEASED

SINGLE-GANG

 

 

 

ELECTRICAL BOX

 

 

Page 1
Image 1
Linear DXS-80 installation instructions Signaling, Carbon, Alarm, Wireless, Monoxide, Installation, Instructions, Listed