| PRODUCT DESCRIPTION |
| |||||
|
| The |
|
|
| CARBON | MOUNTING | ||
|
| designed for use with Linear’s DXS and DX Format receivers. The | ALARM |
|
| ||||
|
|
|
| detector gives warning to alert against both the acute and chronic | SOUNDER |
|
| MONOXIDE | PLATE |
|
|
| BY | effects of CO poisoning. When carbon monoxide is detected, the alarm |
|
|
| ALARM |
|
|
|
|
|
|
|
|
| ||
WIRELESS |
|
| sounds a loud local alarm. When the local alarm sounds, the |
|
|
|
|
| |
|
| transmitter sends a digitally coded wireless signal to its companion |
|
|
|
|
| ||
CARBON |
|
| receiver every 20 seconds until the air has cleared and the detector |
|
|
|
|
| |
|
| is restored. |
|
|
|
|
| ||
MONOXIDE |
|
| The local alarm can be silenced once by pressing the TEST/RESET |
|
|
|
|
| |
|
| button. The transmitter will continue to send an alarm signal every 20 |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
ALARM |
|
| seconds. After 7 minutes, the alarm will sound again if there is still an | TEST/RESET | MOUNTING |
| |||
|
| unsafe CO concentration level. The reset function can be used only | SCREWS & |
| |||||
|
| BUTTON |
|
| |||||
|
|
|
| once for each alarm occurrence. |
| ANCHORS |
| ||
|
|
|
|
|
|
|
| ||
|
|
|
| The DXS transmitters are precoded at the factory to one of over a |
|
|
| ALARM SIGNALS | |
|
|
|
| million possible unique system codes, so no field coding is required. |
|
|
| ||
|
|
|
| NORMAL |
|
|
|
| |
|
|
|
| Receivers must be programmed to the transmitter’s code before | GREEN LED FLASHES EVERY 10 SECONDS. | ||||
Installation |
|
| OPERATION | ||||||
| SIGNALING | system testing and operation. Refer to the receiver’s instructions for |
| A REPEATING PATTERN OF FOUR SHORT BEEPS AND | |||||
Instructions |
| details on programming. | ALARM | 5 SECOND SILENCE. THE RED LED WILL FLASH ONCE | |||||
|
| The unit is powered by one | SIGNAL | PER SECOND. |
| ||||
|
|
|
| with the transmitter and can power the unit for more than one year. If the |
| DETECTOR | |||
|
|
|
| battery voltage drops below a preset level the alarm will sound a low |
| ||||
|
|
| ® | TROUBLE IS DETECTED, RED LED WILL BLINK ONCE EVERY | |||||
|
|
|
| battery chirp every 45 seconds and a low battery signal will be sent to | |||||
|
|
| LISTED | SIGNAL 5 SECONDS AND DETECTOR WILL BEEP EVERY 45 | |||||
|
|
| the receiver (some receivers can report low battery, others cannot). | ||||||
|
|
|
| SECONDS. |
| ||||
|
|
|
| When the detector reaches the end of its serviceable life (after about 6 | LOW BATTERY RED LED BLINKS EVERY 45 SECONDS. | ||||
|
|
|
| years) a permanent trouble condition will occur and cannot be reset. | |||||
|
|
|
| SIGNAL | REPLACE THE BATTERY WHEN THIS SIGNAL OCCURS. | ||||
|
|
|
| Maintenance: Occasionally clean the outside casing with a cloth. |
| RED LED WILL BLINK ONCE EVERY 10 SECONDS AND | |||
|
|
|
| Ensure that the holes on the front of the alarm are not blocked with dirt |
| ||||
|
|
|
| ||||||
| USA & Canada (800) | and dust. Do not paint, and do not use cleaning agents, bleach, or | SIGNAL | CONDITION,THE DETECTOR REQUIRES IMMEDIATE | |||||
| (760) | polish on the detector. |
| REPLACEMENT. |
| ||||
|
| www.linearcorp.com |
|
|
|
|
|
| |
| SELECT PROPER LOCATION | REMOVE MOUNTING PLATE |
| REMOVE BATTERY TAB | |||||
REFER TO SECTION |
| Kitchen Dining Bedroom |
|
|
| NOTE: ON | |||
NUMBER 5 ON THE |
| Room |
|
|
| ||||
Family Room |
| TWIST MOUNTING |
|
| GREEN LEDS WILL BLINK 4 TIMES, | ||||
REAR OF THESE |
|
|
| ||||||
| Living Room |
|
| 15 SECONDS APART WHILE | |||||
INSTRUCTIONS FOR |
| PLATE TO UNLOCK | REMOVE |
| |||||
| Bedroom |
| THE ALARM INITIALIZES. | ||||||
IMPORTANT MOUNTING |
|
|
| BATTERY TAB | |||||
|
|
|
|
|
| ||||
DETAILS |
| = Carbon Monoxide |
|
|
|
| |||
|
| TO APPLY |
|
|
|
| |||
|
|
|
|
|
|
|
| ||
|
| Bedroom | alarm location |
| POWER |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| FIGURE 1. RECOMMENDED |
|
|
|
|
|
|
|
|
| CO ALARM PLACEMENT FOR |
|
|
|
|
|
|
|
|
| SINGLE FLOOR RESIDENCE |
|
| CONNECT BATTERIE |
|
| |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| S |
|
|
Bedroom |
|
|
|
|
|
|
|
| |
Bedroom | Bedroom |
| FIGURE 2. RECOMMENDED |
|
| TO |
|
|
|
|
|
|
|
| PULL |
|
|
| |
Living | Kitchen |
| CO ALARM PLACEMENT FOR |
|
|
|
|
| |
Garage |
|
|
|
|
|
| |||
|
|
|
|
|
|
| |||
Room |
|
|
|
|
|
|
| ||
Basement | = Carbon Monoxide alarm |
|
|
|
|
|
| ||
|
| location for |
|
|
|
|
|
| |
|
| residence |
|
|
|
|
|
| |
|
|
| Inside wall location |
|
|
|
|
|
|
FIGURE 3. RECOMMENDED |
| REMOVE |
|
|
|
|
| ||
| MOUNTING | ||||||||
CO ALARM MOUNTING | Height 5' - 6' from floor | ||||||||
LOCATION IS 5 TO 6 FEET |
| PLATE | PANASONIC CR123A, SANYO CR123A, ADEMCO 466. | ||||||
FROM FLOOR |
|
|
| AVAILABLE AT LOCAL RETAILERS AND INTERNET | |||||
|
|
|
|
| SUPPLIERS. NOTE: USE ONLY THESE SPECIFIC | ||||
|
|
| = Carbon Monoxide alarm |
| BATTERY MODELS. |
| |||
|
|
| mounting location |
|
|
|
|
|
|
| INSTALL MOUNTING PLATE | PROGRAM RECEIVER | MOUNT ALARM ON PLATE | ||||||
|
| SCREW | REFER TO RECEIVER'S INSTRUCTIONS TO | TWIST CO ALARM CLOCKWISE TO | |||||
|
| PREPARE RECEIVER TO ACCEPT THE | LOCK ONTO MOUNTING PLATE | ||||||
|
| ANCHORS | |||||||
|
| TRANSMITTER'S CODE |
|
|
|
|
| ||
|
| FOR WALLBOARD |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
PRESS UNTIL ALARM
BEEPS THEN RELEASE
TEST BUTTON TO
SEND SIGNAL
OR
| A TEST SIGNAL WILL BE SENT A | ALIGN TAB IN PLATE WITH | |
PLASTIC | FEW SECONDS AFTER THE | ||
NOTCH IN COVER | |||
SWITCH IS RELEASED | |||
| |||
|
| ||
ELECTRICAL BOX |
|
|