Radio Operation (continued)

TA Seek / TA Alarm

In TA Alarm mode, the alarm is set off.

1.Press and hold the VOL knob for a few sec- onds then release.

2.Continue to press the knob until “TA ALARM” appears in the display.

3.Rotate the VOL knob until “TA SEEK” appears in the display. In TA SEEK mode, the unit will seek for Traffic Announcement program.

PTY (Program Type)

1.Press and hold DIS button to activate the PTY function.

2.Rotate the VOL knob to select the PTY type.

3.When the program type you want to search for is displayed, press the DIS button to search for the selected program type. Press the DIS but- ton again to stop the PTY search.

Note: If PTY code is different or not available, LCD blinks with “PTY NONE”.

Sound Controls

Volume

Rotate the VOL knob clockwise to increase the vol- ume and counterclockwise to decrease the volume.

Sound Characteristics Menu

By pressing the VOL knob, the modes will be displayed in the following order: Volume, Bass, Treble, Balance and Fader.

Bass

Press the VOL knob two times. Turn the VOL knob clockwise to increase the bass and counterclock- wise to decrease the bass.

Treble

Press the VOL knob button three times. Turn the VOL knob clockwise to increase the treble and counterclockwise to decrease the treble.

Balance

Press the VOL knob button four times. Turn the VOL knob clockwise to increase the balance to the right and counterclockwise to increase the balance to the left.

Fader

Press the VOL knob button five times. Turn the VOL knob clockwise to increase the balance to the front speakers and counterclockwise to increase the balance to the rear speakers.

Equalizer

The M3300CD has pre-programmed audio set- tings. To switch the equalizer settings push and hold the VOL knob for a few seconds then release. One of the following equalizer setting will appear: POP M, ROCK M, DSP OFF, FLAT or CLASSICS. Rotate the VOL knob until the desired setting appears in the display. The unit will leave equalizer programing after 5 seconds of no but- ton activity.

Note: If the bass or treble is adjusted the equal- izer setting will revert to the DSP OFF setting.

Loud

Enhances high frequency and low frequency sound quality. To switch the loudness push and hold the VOL knob for a few seconds then release. Continue to press the knob until “LOUD OFF” appears in the display. Rotate the VOL knob until “LOUD ON” appears in the display. The unit will leave feature programing after 5 seconds of no button activity.

Mute

Press the PWR/MUTE button to turn the sound off. Press it again to restore the audio.

Sub Woofer

Press and hold the MODE button to enable or disable the Sub Woofer output. When the Sub Woofer output is enabled, “SW” appears in the display.

5

Page 5
Image 5
Linear M3300CD installation manual Sound Controls

M3300CD specifications

The Linear M3300CD is an advanced control panel designed for use in security and access control systems. Engineered to provide robust performance and reliability, the M3300CD is a popular choice for both residential and commercial applications.

One of the standout features of the M3300CD is its ability to support a variety of communication technologies, ensuring seamless integration with existing systems. It utilizes a powerful microprocessor that enhances processing speed and efficiency, enabling the system to manage multiple security devices without compromising performance.

This control panel supports both wired and wireless devices, which allows for greater flexibility in installation and expansion. The ability to connect wireless sensors and keypads reduces the complexity and time required for installation, making it an ideal choice for users seeking a hassle-free setup.

The M3300CD also incorporates advanced encryption technologies, providing enhanced security for transmitted data. This is crucial for preventing unauthorized access and ensuring that all communication within the security system is safeguarded against potential cyber threats.

Another key characteristic of the M3300CD is its user-friendly interface. The panel features an easy-to-read LCD display that allows users to view system status, customize settings, and execute commands intuitively. Customizable user codes can be programmed, allowing multiple users to access the system while maintaining an audit trail of activities.

Moreover, the M3300CD is equipped with an extensive event log that can store up to 500 events, making it easier for users to monitor and review system activity. This feature is particularly beneficial for commercial environments where tracking access and security events is crucial.

With its adaptable design, the M3300CD is compatible with a wide range of sensors, including motion detectors, door/window contacts, and glass break sensors, providing comprehensive coverage for various security needs.

In summary, the Linear M3300CD stands out as an exceptional control panel with its advanced communication capabilities, easy installation options, strong security features, and user-friendly interface. Its versatility and reliability make it a preferred solution for anyone looking to enhance their security infrastructure efficiently and effectively.