Linear T-90 Step, OPTIONAL LONG LIFE BATTERIES To increase the, For External Contacts Only

Models: T-90

1 2
Download 2 pages 33.6 Kb
Page 2
Image 2
STEP 7

STEP 7

Attach mounting plates. Use the screws or

*** FOR EXTERNAL CONTACTS ONLY ***

*** FOR EXTERNAL CONTACTS ONLY ***

double-stick tape provided to affix the mounting plates. Be sure

STEP 8

Change contact jumper. Remove the side select

STEP 9

Install contact or sensor and

transmitter

the magnet will be adjacent to the magnet alignment marks.

jumper and place it on the internal contact disable pins.

mounting plate. Mount the external contact or sensor as

Mount the magnet no further than 1/2 inch from the transmitter.

 

 

 

 

 

described in its instructions. For recessed wiring, drill an

Snap transmitter and magnet onto mounting plates.

 

 

MOVE JUMPER FROM HERE

FOR INTERNAL CONTACTS, SKIP TO STEP 11

 

 

(3-PIN SIDE SELECT POSTS)

access hole for the wire.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

1

TO HERE

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

(2-PIN INTERNAL CONTACT

 

 

 

 

 

 

 

 

 

 

DISABLE POSTS)

 

 

 

*** FOR EXTERNAL CONTACTS ONLY ***

STEP 11

Complete transmitter

setup. Set option

STEP 12

Close transmitter case. Close the case by

switch #2 to enable or disable the 2-minute wait timer. Setting

locking the top together first, then snap the bottom together.

STEP 10 Connect to terminals and set option switch.

switch #2 ON enables 2-minute wait timer (after triggering, unit

 

 

 

Connect two wires from the external sensor to the external

 

 

 

waits 2 minutes before re-triggering). Switch #3 must be off

 

 

 

contact terminals. Set the option switches for the type of sensor.

 

 

 

when only using the internal contacts.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SET SWITCH #2 OFF (OPEN) FOR

 

SET SWITCH #2 ON FOR

LOCK TOP

 

 

 

 

 

 

LOW ACTIVITY DEVICES (DOOR

 

 

HIGH ACTIVITY DEVICES

TOGETHER

 

 

 

 

 

 

SWITCHES, WATER SENSORS,

 

 

(MAT SWITCHES, PIR'S, ETC.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WINDOW SCREENS, ETC.)

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

4

 

 

 

 

 

 

 

 

 

3

 

 

3

 

 

 

 

 

 

 

 

 

2

 

 

2

 

 

 

 

 

 

 

 

 

1

 

 

1

 

 

 

 

 

 

 

 

 

N

 

 

N

 

 

 

 

 

 

 

 

 

E

 

 

E

 

 

 

 

 

 

 

 

 

P

 

 

P

 

 

 

 

 

 

 

 

 

O

 

 

O

 

 

 

 

 

 

 

 

 

 

OPEN = OFF

 

THEN SNAP

 

 

 

 

 

 

 

 

 

 

 

CASE SHUT

 

 

 

 

 

 

TRANSMITTER WILL ACTIVATE

 

TRANSMITTER CAN ACTIVATE

 

 

 

 

 

 

 

 

EACH TIME IT IS TRIGGERED

 

ONLY ONCE EVERY TWO MINUTES

 

 

 

STEP 13

 

Program transmitter into receiver and test.

OPTIONAL LONG LIFE BATTERIES To increase the

LINEAR LIMITED WARRANTY

 

Follow the receiver’s instructions to set it in a program or learn

battery life of the unit in high traffic uses, replace the two type

This Linear product is warranted against defects in material and workmanship for twelve (12) months. The

Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who

mode. Press the bottom of the transmitter case to send a test

CR2032 with two DL2450 batteries. Exchange the battery

buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product

to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if

signal. Verify that the signal was received and that the transmitter

clamp for the taller one provided, and remove the battery

any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising

out of or in connection with use or performance of this product or other indirect damages with respect

was properly entered into

 

reduction ring.

 

 

 

 

 

 

 

to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation. All implied

the receiver’s memory.

 

 

 

 

 

 

warranties, including implied warranties for merchantability and implied warranties for fitness, are valid only until

 

SHORT

 

 

SCREW

Warranty Expiration Date as labeled on the product. This Linear LLC Warranty is in lieu of all other warranties

Set the receiver

into a

 

 

 

express or implied.

 

 

CLAMP

DL2032/CR2032

 

All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact

monitor or chime mode.

 

 

Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.

 

 

 

BATTERIES

 

 

 

 

 

TALL

Linear radio controls provide a reliable communications link and fill an important need in portable wireless

Open the door or window

 

 

 

 

 

 

signalling. However, there are some limitations which must be observed.

 

 

 

 

 

CLAMP

 

monitored

by

the

 

REDUCTION

 

IMPORTANT !!!

 

 

 

 

 

 

transmitter

and

verify

PRESS TO

RING

 

 

DL2450

Linear radio controls provide a reliable communications link and fill an important need in portable wireless

 

 

signalling. However, there are some limitations which must be observed.

 

 

 

 

 

that the receiver accepts

SEND TEST

 

 

 

BATTERIES

 For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15

 

 

 

 

 

devices. As such, they have limited transmitter power and therefore limited range.

 

the alarm

transmission.

SIGNAL

 

 

 

 

 

 A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals

Close the door or window

 

 

 

 

 

 

that occur on or near their operating frequencies, regardless of code settings.

 

 

 

 

 

 

 

 Changes or modifications to the device may void FCC compliance.

 

and verify that the restore

 

 

 

 

 

 

 Infrequently used radio links should be tested regularly to protect against undetected interference or fault.

OPEN & CLOSE

 

 

 

 

 

 A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or

signal was accepted.

 

 

 

 

 

DOOR FOR

 

SLIDE CLAMP

 

dealer, and these facts should be communicated to the ultimate users.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM & RESTORE

 

THROUGH SLOT

 

Copyright © 2006 Linear LLC

207138 F

Page 2
Image 2