PRECAUTIONS
Note: These fireplace systems are not difficult to install. However, in the interest of safety, it is recommended that the installer be a qualified or certified “tradesman” familiar with commonly accepted fireplace installation and safety techniques as well as prevailing local codes.
The most important areas of concern dealing with the installation of
IMPORTANT: WHEN INSTALLING IN CANADA, THE CHIMNEY AIR KIT MUST BE INSTALLED PER THE WARNOCK HERSEY INC. LISTING.
IMPORTANT: THE MINIMUM AIR SPACE TO COMBUSTIBLES FOR THE CHIMNEY SYSTEM IS 2" (51 MM).
TYPICAL INSTALLATION
Chimney
and
Termination
Optional Position
Outside Combustion Air Kit (Optional)
Figure 1
INTRODUCTION
General Information
These fireplaces are conventional radiant heat fireplaces with standard bar grates, optional outside combustion air kits and optional decorative glass doors.
Note: Illustrations shown reflect “typical” installations with nominal dimensions and are for design and framing reference only. Actual installations may vary due to individual design prefer- ences.However,alwaysmaintainminimumclearances to combustible materials and do not violate any specific installation requirements.
The Colonial Series fireplaces have been tested and listed by Warnock Hersey Inc. (Report No.
These fireplace systems are designed for installation in accordance with the National Fire Protection Standard for chimneys, fireplaces and solid fuel burning appliances; NFPA 211 and in accordance with codes such as the BOCA Basic/National Codes, the Standard Mechanical Code, Uniform Building Codes and/or the Canadian National Code.
Chimney
Air Kit
(Canada Only)
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
WARNING: FAILURE TO USE MANUFACTURE PROVIDED PARTS, VARIATIONS IN TECHNIQUES AND CONSTRUCTION MATERIALS OR PRACTICES OTHER THAN THOSE DESCRIBED IN THIS MANUAL MAY CREATE A FIRE HAZARD AND VOID THE LIMITED WARRANTY.
When complete these fireplace systems consist of five basic
1.The Fireplace
2.The Chimney and Termination
3.The Optional Glass Doors
4.The Optional Combustion Air Kit
5.The Chimney Collar Enclosure Kit (Canada Only)
CLEARANCES AND HEIGHT
REQUIREMENTS
The fireplace may be placed on or near normal construction materials*. The combustion air kit, firestop spacer and roof flashings (not chase flashings) may be placed directly on or against normal construction materials*. The chimney requires a minimum 2" (51 mm) air space to combustibles. A combustible mantle may be installed a minimum of 12" (305 mm) above the opening of the fireplace as per NFPA 211, Section
The fireplace and chimney system must be enclosed when installed in or passing through a living area where combustibles or people may come in contact with it. This is important to prevent possible personal injury or fire hazard.
For questions, please call your distributor or the manufacturer. Special restrictions apply to the front and facing of the fireplace and nearby walls (See pages 16 and 17 ).
CHIMNEY SYSTEM
These fireplaces are designed and code listed for use with Security Chimneys FTF10 chimney System only. Always use Security Chimneys FTF10 chimney components with these fire- places. Do not modify or alter these components as this may cause a potential serious hazard and void the Warranty.
*Construction Materials: |
|
• framing materials | • paneling |
• particle board | • flooring |
• dry wall | • etc. |
• plywood |
|