Linksys HPB200 manual Telephone Cabling, Environmental Specifications

Models: HPB200

1 9
Download 9 pages 41.71 Kb
Page 8
Image 8

Linksys HomeLink™ Series

Telephone Cabling

The telephone cables you use to build your HomeLink network can be either crossover or straight-through cables. The connectors on phone cables are called RJ-11 connectors, and have four wires inside the plastic tips.

Standard telephone cables like the ones you use every day in your home should do the job.

Phoneline 10M Ethernet Bridge

Specifications

Standards

IEEE 802.3, IEEE 802.3u, HPNA 1.0 and 2.0

 

Compatible

 

Protocol

CSMA/CD

 

Ports

1 RJ-11 Standard Modular Telephone Port

 

2 10BaseT/100BaseTx RJ-45 Ports

 

(Includes One Shared Uplink)

Cabling Type

Phoneline: Standard RJ-11 Telephone Cable

 

10BaseT: UTP Category 3 or better

 

100BaseTx: UTP Category 5 or better

Topology

Star or Daisy Chain

Speed

1Mbps or 10Mbps (Phoneline)

 

Full Duplex: 20Mbps or 200Mbps

 

Half Duplex: 10Mbps or 100Mbps

LEDs

Power

 

 

HPNA: Link,Tx,Rx

 

LAN: Link,Tx,Rx

 

 

Environmental Specifications

 

Environmental Specifications

 

Dimensions:

7.31" x 6.16" x 1.88" (186mm x 154mm x 48mm)

Unit Weight:

12 oz. (0.34 kg)

 

Power Input:

External, 5V DC, 3A

Certifications:

FCC Class B, CE Mark Commercial

Operating Temp.:

32°F to 122°F

(0°C to 49°C)

Storage Temp.:

-4°F to 158°F

(-20°C to 70°C)

Operating Humidity:

10% to 85% Non-condensing

Operating Humidity:

5% to 90% Non-condensing

10

11