The user returns to the main menu by pressing either the Menu button or the Enter button.

Normal Operation

Powering up

Switch on power at the CU 6010. After powering up, the display on the CU 6010 is showing the Start-up screen:

Initializing

Please Wait

Digital Conference

System 6000

DIS

Registration Mode

Unit registration

Microphones disabled

After initialising the following screens are displayed:

-Audio control

-Delegate setup

 

-Interpreter setup

 

-Ambient Microphone

 

 

-Loudspk volume: 0dB ▲

-LineOut volume: 0dB

-Mic->Loudspk: -9dB

-Mic->LineOut: 2dB ▼

This screen is the standard screen showed at normal use. This screen is automatically shown if no buttons is pressed in 2 minutes. The function of this screen is explained in the section Audio Control

menu.

Use with SW 6000

Please refer to the SW 6000 manuals.

Schematics volume/gain settings

The volume controls, which can be set on the CU 6010 user interface as described in the previous section are shown in the following schematic.

￿Setting of Loudspeaker volume

1.Set the Mic>Loudspk to 0dB

2.Turn up the Loudspk Volume to the level needed in the loudspeakers.

￿Setting Line input level

1.Apply the signal to the Input connector

2.Turn up the input level on “LineInlevel Adj” until you can see the overflow indicator.

-LineIn->Loudspk: -17dB

-LineIn->LineOut: 10dB >LineInLevel Adj:* -6dB

-Loudspk volume: 3dB ▼

”*” Overflow indicator on line input

3.Turn then the InputIn level down –8 dB to –12dB from the clipping level. Depending of the source connected, there might be different “overhead” needed. But normally 8-12 db is enough.

4.Turn up the Linein >Loudspk Volume to the level needed in the loudspeakers

The principle is that the level of signal from the Line Input is combined of two settings:

“LinelnLevel Adj” and “ LineIn->Loudspk” .