Danish Interpretation Systems | User Manual |
The user returns to the main menu by pressing either the Menu button or the Enter button.
Normal Operation
Powering up
Switch on power at the CU 6010. After powering up, the display on the CU 6010 is showing the
Initializing
Please Wait
Digital Conference
System 6000
DIS
Registration Mode
Unit registration
Microphones disabled
After initialising the following screens are displayed:
▲ | |
| |
| |
▼ | |
|
|
This screen is the standard screen showed at normal use. This screen is automatically shown if no buttons is pressed in 2 minutes. The function of this screen is explained in the section Audio Control
menu.
Use with SW 6000
Please refer to the SW 6000 manuals.
Schematics volume/gain settings
The volume controls, which can be set on the CU 6010 user interface as described in the previous section are shown in the following schematic.
Setting of Loudspeaker volume
1.Set the Mic>Loudspk to 0dB
2.Turn up the Loudspk Volume to the level needed in the loudspeakers.
Setting Line input level
1.Apply the signal to the Input connector
2.Turn up the input level on “LineInlevel Adj” until you can see the overflow indicator.
”*” Overflow indicator on line input
3.Turn then the InputIn level down
4.Turn up the Linein >Loudspk Volume to the level needed in the loudspeakers
The principle is that the level of signal from the Line Input is combined of two settings:
“LinelnLevel Adj” and “ LineIn->Loudspk” .