User’s Information Manual

2Maintenance schedule (continued)

4.Fill with fresh water until the water begins to pour out of the drain.

5.Replace the cap. Press the cap onto the trap until the cap makes contact with the drain.

6.Replace the retaining screw.

The condensate trap (FIG. 2-1) must be ￿ WARNING filled with water during all times of boiler

operation to avoid flue gas emission from the condensate drain line. Failure to fill the trap could result in severe personal injury or death.

Figure 2-1Condensate Trap

Condensate disposal

NOTICE

Use materials approved by the authority

having jurisdiction. In the absence of

 

 

 

other authority, PVC and CPVC pipe must

 

comply with ASTM D1785 or D2845.

 

Cement and primer must comply with

 

ASME D2564 or F493. For Canada use

 

CSA or ULC certified PVC or CPVC pipe,

 

fittings, and cement.

 

To allow for proper drainage on large

NOTICE

horizontal runs, a second line vent may be

 

 

required and tubing size may need to

 

increase to 1 inch.

The condensate line must remain unobstructed, allowing free flow of condensate. If condensate is allowed to freeze in the line or if the line is obstructed in any other manner, condensate can exit from the boiler tee, resulting in potential water damage to property. Call your qualified service technician to inspect the boiler and system.

7.A condensate removal pump is required if the boiler is below the drain. When installing a condensate pump, select one approved for use with condensing boilers and furnaces. The pump should have an overflow switch to prevent property damage from condensate spillage. Call

your qualified service technician to inspect the boiler and system.

1. This boiler is a high efficiency appliance that produces Figure 2-2Condensate Disposal condensate.

2. The bottom of the boiler has a 1/2 inch pipe for connection of a 1/2 inch PVC pipe (FIG. 2-2).

3. Slope condensate tubing down and away from the boiler into a drain or condensate neutralizing filter. Condensate from the Knight wall mount boiler will be slightly acidic (typically with a pH from 3 to 5). Install a neutralizing filter if required by local codes. Call your qualified service technician to inspect the boiler and system.

A Neutralizer Kit is available from the factory (Kit #3087). Call your qualified service technician to install.

4.Do not expose condensate line to freezing temperatures.

5.Use only plastic tubing or piping as a condensate drain line (FIG. 2-2).

6.Leave the top of the tee assembly installed in the unit open, this is needed as a vacuum break. The blocked drain switch will shut the boiler down before any condensate can flow out of the tee.

7

Page 7
Image 7
Lochinvar 50, 210 manual 1Condensate Trap, Condensate disposal

50, 210 specifications

The Lochinvar 210,50 is a high-efficiency, commercial-grade heating boiler that has garnered acclaim for its robust performance and advanced features. Designed for large-scale applications, the Lochinvar 210,50 stands out due to its innovative technologies that enhance energy efficiency and operational reliability.

One of the defining characteristics of the Lochinvar 210,50 is its exceptional power output. With a heating capacity of 210,000 BTU/hr, this boiler is engineered to meet the demands of extensive heating systems, making it suitable for various commercial settings, including schools, hospitals, and industrial facilities. It is capable of providing consistent and reliable heating, ensuring optimal comfort for occupants even in the coldest months of the year.

The Lochinvar 210,50 incorporates advanced condensing technology, which allows for higher efficiency levels than traditional non-condensing boilers. By capturing and reusing the heat from flue gases, it achieves efficiency ratings of up to 96%. This not only reduces energy consumption but also lowers greenhouse gas emissions, supporting sustainability efforts within various industries.

Further enhancing its appeal, the Lochinvar 210,50 features a stainless steel heat exchanger designed to withstand rigorous operating conditions while maximizing heat transfer. This robust construction contributes to the longevity and durability of the boiler, ensuring fewer maintenance requirements and reduced total cost of ownership over time.

The boiler is also equipped with intuitive control systems that simplify operation and monitoring. With features such as a user-friendly interface and integrated diagnostic tools, service technicians can quickly identify and resolve issues, maximizing uptime and efficiency. The Lochinvar 210,50 is compatible with advanced building management systems, allowing for seamless integration into existing infrastructure.

In terms of safety, the Lochinvar 210,50 includes multiple safety features such as flame safety systems, pressure limit switches, and high-temperature limit controls. These components work together to ensure that the boiler operates within safe parameters, reducing the risk of malfunctions and enhancing peace of mind for facility managers.

In conclusion, the Lochinvar 210,50 is a versatile and efficient heating solution that combines advanced technology, exceptional performance, and reliability. Its design caters to the rigorous demands of commercial applications, making it an ideal choice for those seeking a high-performance heating boiler. With its commitment to energy efficiency, durability, and safety, the Lochinvar 210,50 is poised to meet the evolving needs of today’s heating industry.