User’s Information Manual

4SMART SYSTEM control module

E: DHW settings

DHW boiler set point

When a DHW call for heat becomes active, the control will use the DHW boiler set point to determine the firing rate of the boiler based on the actual water temperature. This parameter can be changed by the installer by accessing parameter E1. The temperature range of this parameter is 50°F to 190°F. The default value is 180°F.

SH/DHW switching time

The SH/DHW switching time parameter sets the length of time the control will stay in DHW Mode when a SH call has been received. After this time period has expired the control will revert to SH Mode. If a DHW call is still active the timer will reset. After the time period has expired the control will revert back to DHW Mode. This will continue until one of the demands has been satisfied. This parameter can be changed by the installer by accessing parameter E2. The time range of this parameter is 10 minutes to 240 minutes. The default value is 30 minutes.

F: Outdoor air reset

Outdoor air shutdown

When the outdoor air shutdown rises above this point, the control will block all SH demands (DHW demands will still be active). This parameter can be changed by the user or the installer by accessing parameter F5. The temperature range of this parameter is 0°F to 120°F. The default value is 80°F.

Outdoor air shutdown differential

The outdoor air shutdown differential parameter is the number of degrees below parameter F5 the outdoor air temperature must go before the boiler will respond to a SH demand. This parameter can be changed by the user or the installer by accessing parameter F6. The temperature range of this parameter is 0°F to 90°F. The default value is 10°F.

Boost temperature

If a SH demand lasts longer than the programmed time delay setting and there have been no DHW demands, the control will increase the water temperature set point by the amount in this parameter. If the SH demand continues through another time period, the set point will be increased again. This will continue until either the SH demand ends, a maximum of 20 increases has occurred, or the maximum set point has been reached. Once the SH demand has been satisfied the set point will revert back to its calculated setting. The boost temperature can be changed by the installer by accessing parameter F8. The temperature range of this parameter is 0°F to 45°F. The default value is 0°F. This feature will be active if this parameter is set to anything other than 0°F.

Boost time

The boost time parameter sets the amount of time that must elapse with a SH demand before the water temperature set point will be increased. This parameter can be changed by the installer by accessing parameter F9. The time range for this parameter is 1 minute to 60 minutes. The default value is 20 minutes.

14

Page 14
Image 14
Lochinvar 210, 50 manual DHW settings, Outdoor air reset

50, 210 specifications

The Lochinvar 210,50 is a high-efficiency, commercial-grade heating boiler that has garnered acclaim for its robust performance and advanced features. Designed for large-scale applications, the Lochinvar 210,50 stands out due to its innovative technologies that enhance energy efficiency and operational reliability.

One of the defining characteristics of the Lochinvar 210,50 is its exceptional power output. With a heating capacity of 210,000 BTU/hr, this boiler is engineered to meet the demands of extensive heating systems, making it suitable for various commercial settings, including schools, hospitals, and industrial facilities. It is capable of providing consistent and reliable heating, ensuring optimal comfort for occupants even in the coldest months of the year.

The Lochinvar 210,50 incorporates advanced condensing technology, which allows for higher efficiency levels than traditional non-condensing boilers. By capturing and reusing the heat from flue gases, it achieves efficiency ratings of up to 96%. This not only reduces energy consumption but also lowers greenhouse gas emissions, supporting sustainability efforts within various industries.

Further enhancing its appeal, the Lochinvar 210,50 features a stainless steel heat exchanger designed to withstand rigorous operating conditions while maximizing heat transfer. This robust construction contributes to the longevity and durability of the boiler, ensuring fewer maintenance requirements and reduced total cost of ownership over time.

The boiler is also equipped with intuitive control systems that simplify operation and monitoring. With features such as a user-friendly interface and integrated diagnostic tools, service technicians can quickly identify and resolve issues, maximizing uptime and efficiency. The Lochinvar 210,50 is compatible with advanced building management systems, allowing for seamless integration into existing infrastructure.

In terms of safety, the Lochinvar 210,50 includes multiple safety features such as flame safety systems, pressure limit switches, and high-temperature limit controls. These components work together to ensure that the boiler operates within safe parameters, reducing the risk of malfunctions and enhancing peace of mind for facility managers.

In conclusion, the Lochinvar 210,50 is a versatile and efficient heating solution that combines advanced technology, exceptional performance, and reliability. Its design caters to the rigorous demands of commercial applications, making it an ideal choice for those seeking a high-performance heating boiler. With its commitment to energy efficiency, durability, and safety, the Lochinvar 210,50 is poised to meet the evolving needs of today’s heating industry.