ITEM

PART

DESCRIPTION

MODEL

NO.

NO.

NO.

 

 

 

 

 

 

 

 

MISCELLANEOUS (Continued)

 

 

34

GKT2429

GASKET BURNER

ALL

35

GKT2427

GASKET ESCUTCHEON

ALL

-

GKT3408

GASKET STRIP

ALL

-

GKT2012

GASKET IGNITOR

ALL

-

GKT30000

ROLL 25' PVC GKT 1/4 X 5/8 W/P

ALL

-

PRS2004

LOW GAS PRESSURE SWITCH - NAT.

C(B, W)N 986-2066

-

MSC3415

SIGHT GLASS KIT

ALL

-

TUB2002

TUBING-AIR PRESSURE BEFORE SERIAL# E05H00176040

ALL

-

TUB2004

TUBING-AIR PRESSURE AFTER SERIAL# E05H00176040

ALL

-

MSC2461

TUBING, SILICONE

ALL

-

MSC7119

CLIP, BULBWELL

ALL

-

WTR2530

LOW WATER CUTOFF, MANUAL RESET (OPTIONAL) PRIOR TO H08H00211329

ALL

-

WTR30000

LOW WATER CUTOFF, MANUAL RESET (OPTIONAL) BEGINNING H08H00211329

ALL

-

WTR2528

LOW WATER CUTOFF, AUTO RESET (OPTIONAL) PRIOR TO H08H00211329

ALL

-

WTR30001

LOW WATER CUTOFF, AUTO RESET (OPTIONAL) BEGINNING H08H00211329

ALL

-

WTR2532

LOW WATER CUTOFF PROBE (OPTIONAL) PRIOR TO H08H00211329

ALL

-

WTR2222

LOW WATER CUTOFF PROBE (OPTIONAL) BEGINNING H08H00211329

ALL

-

WTR2533

LOW WATER CUTOFF BOOT (OPTIONAL) PRIOR TO H08H00211329

ALL

-

WTR20000

LOW WATER CUTOFF BOOT (OPTIONAL) BEGINNING H08H00211329

ALL

 

 

LOCH-HEAT TILE

 

 

36

FIB2204

INSULATION FRONT HEAD SIDE PANEL

ALL

37

FIB2205

INSULATION REAR HEAD SIDE PANEL

ALL

38

FIB2228

DIVIDER PANEL

ALL

39

FIB2231

FRONT PANEL

C(B,W)986

39

FIB2232

FRONT PANEL

C(B,W)1256

39

FIB2233

FRONT LEFT PANEL

C(B,W)1436

40

FIB2234

FRONT RIGHT PANEL

C(B,W)1436

39

FIB2220

FRONT LEFT PANEL

C(B,W)1796

40

FIB2236

FRONT RIGHT PANEL

C(B,W)1796

39

FIB2254

FRONT LEFT PANEL

C(B,W)2066

40

FIB2255

FRONT RIGHT PANEL

C(B,W)2066

-

FIB2203

BACK PANEL

C(B,W)986

-

FIB2209

BACK PANEL

C(B,W)1256

-

FIB2217

INSULATION, BACK RIGHT

C(B,W)1436,1796,2066

-

FIB2216

INSULATION, BACK LEFT

C(B,W)1436

-

FIB2229

INSULATION, BACK LEFT

C(B,W)1796

-

FIB2230

INSULATION, BACK LEFT

C(B,W)2066

-

FIB2258

INSULATION PAD, BACK

C(B,W)986,1256,1436

-

FIB2260

INSULATION PAD, BACK

C(B,W)1796,2066

-

FIB2257

INSULATION PAD, TOP

C(B,W)986,1256,1436

-

FIB2259

INSULATION PAD, TOP

C(B,W)1796,2066

-

FIB2256

INSULATION PAD, RIGHT SIDE

ALL

 

 

LOCH-HEAT TILE BOTTOM PANELS

 

 

41

FIB2206

BOTTOM PANEL POSITION 1*

C(B,W)986

41

FIB2207

BOTTOM PANEL POSITION 2*

C(B,W)986

41

FIB2208

BOTTOM PANEL POSITION 3*

C(B,W)986

41

FIB2211

BOTTOM PANEL POSITION 1*

C(B,W)1256

41

FIB2212

BOTTOM PANEL POSITION 2 & 3*

C(B,W)1256

41

FIB2207

BOTTOM PANEL POSITION 4*

C(B,W)1256

41

FIB2218

BOTTOM PANEL POSITION 1*

C(B,W)1436

41

FIB2207

BOTTOM PANEL POSITION 2 & 3*

C(B,W)1436

41

FIB2219

BOTTOM PANEL POSITION 4*

C(B,W)1436

41

FIB2222

BOTTOM PANEL POSITION 1*

C(B,W)1796

41

FIB2207

BOTTOM PANEL POSITION 2, 3, & 4*

C(B,W)1796

41

FIB2223

BOTTOM PANEL POSITION 5*

C(B,W)1796

41

FIB2226

BOTTOM PANEL POSITION 1*

C(B,W)2066

41

FIB2212

BOTTOM PANEL POSITION 2*

C(B,W)2066

41

FIB2207

BOTTOM PANEL POSITION 3, 4, & 5*

C(B,W)2066

41

FIB2227

BOTTOM PANEL POSITION 6*

C(B,W)2066

*DENOTES PLACEMENT ORDER OF COMBUSTION CHAMBER BOTTOM TILE FROM LEFT TO RIGHT (Front to rear heat exchanger head)

NOTE: CB = BOILER, CW = WATER HEATER

PLEASE HAVE MODEL NUMBER AND SERIAL NUMBER WHEN ORDERING PARTS.

CB-CW(E)-RP-03

4 of 4

10/08 - Printed in U.S.A.

Page 4
Image 4
Lochinvar CB986-2066 manual Part Description Model, LOCH-HEAT Tile Bottom Panels

CB986-2066 specifications

The Lochinvar CB986-2066 is a cutting-edge commercial boiler designed specifically for high efficiency and reliable hot water heating in commercial applications. With a focus on maximizing energy efficiency and reducing operational costs, this model stands out as a top choice for businesses looking to optimize their heating systems.

One of the main features of the Lochinvar CB986-2066 is its impressive heating capacity. It boasts a robust output of 986,000 BTU/hr, making it suitable for large facilities that require consistent and dependable heating. The boiler is designed with a stainless steel heat exchanger, which not only enhances durability but also improves heat transfer efficiency. This results in lower energy consumption and reduced greenhouse gas emissions, contributing to a more sustainable operation.

Another key technology incorporated into the CB986-2066 is the advanced control system. The boiler is equipped with a user-friendly touchscreen display that allows operators to monitor performance in real-time, adjust settings easily, and access diagnostic information. This smart control system enhances operational efficiency by optimizing performance based on demand, making it adaptable to varying heating needs throughout the day.

In terms of safety, the Lochinvar CB986-2066 incorporates several important features. It includes a multi-layered approach to safety, with built-in safeguard controls that monitor pressure, temperature, and flow rates to prevent any potential hazards. Additionally, it comes with a robust ventilation system that ensures proper exhaust of combustion gases, contributing to a safe working environment.

The installation of the Lochinvar CB986-2066 is straightforward, thanks in part to its compact design, which allows for flexibility in placement. Its lightweight construction makes it easy to transport and position within a facility. Moreover, the boiler is designed to meet various industry standards, ensuring compliance with local codes and requirements.

In summary, the Lochinvar CB986-2066 is a superior commercial boiler known for its high efficiency, advanced technology, and robust safety features. With its impressive heating capacity, user-friendly controls, and durable construction, it is an ideal solution for businesses seeking reliable and efficient hot water heating solutions. Whether used in hospitals, educational institutions, or industrial settings, the CB986-2066 aligns with modern energy efficiency goals while delivering consistent performance.