Commercial Electric Steam Boiler Dimensions & Specifications
Top View
Note 1: Element removal clearance (R”) is equal to 2 times the element KW.
|
| Max. | Steam | Max. |
| Connection Sizes (NPT) |
| Tank Data |
|
|
|
| Weight | |||||
| Model | Input F&A 212°F | # of | Feed | Blowdown | Steam Outlet | Dims | Vol | Dimensions (Inches) | (lbs) | ||||||||
| Number kW | (PPH) | Elements | Water 15psi | >15psi 15psi | 50psi 150psi | (In) | (Gal) | A | B | C | D | Ship | Oper. | ||||
| BS*12 | 60 | 205 | 3 | 1/2" | 3/4" | 3/4" | 1" | 3/4" | 12x42 | 20 | 22" | 28" | 50" | 25" | 550 | 650 | |
| BS*16 | 140 | 478 | 7 | 1/2" | 3/4" | 3/4" | 2" | 1" | 3/4" | 16x42 | 32 | 26" | 32" | 50" | 33" | 750 | 910 |
| BS*16 | 200 | 682 | 10 | 1/2" | 3/4" | 3/4" | 2" | 3/4" | 16x42 | 32 | 26" | 32" | 54" | 33" | 800 | 960 | |
| BS*20 | 240 | 819 | 12 | 3/4" | 1" | 1" | 1" | 20x42 | 41 | 30" | 36" | 50" | 51" | 1000 | 1200 | ||
| BS*20 | 320 | 1092 | 18 | 3/4" | 1" | 1" | 3" | 1" | 20x42 | 41 | 30" | 36" | 54" | 51" | 1050 | 1250 | |
| BS*24 | 360 | 1228 | 18 | 3/4" | 1" | 3" | 24x44 | 74 | 34" | 40" | 52" | 51" | 1300 | 1670 | |||
| BS*24 | 600 | 2047 | 30 | 3/4" | 1" | 4" FLG | 2" | 24x44 | 74 | 34" | 40" | 56" | 51" | 1400 | 1770 | ||
| BS*30 | 960 | 3276 | 48 | 3/4" | 1" | 6" FLG | 3" FLG | 2" | 30x46 | 124 | 40" | 48" | 60" | 63" | 1700 | 2340 | |
| BS*36 | 1280 | 4367 | 64 | 1" | 1" | 6" FLG | 3" FLG | 2" | 36x46 | 166 | 46" | 54" | 60" | 63" | 2100 | 2960 | |
| BS*42 | 1880 | 6415 | 94 | 1" | 1" | 8" FLG | 4" FLG | 3" FLG | 42x48 | 230 | 52" | 62" | 64" | 81" | 2800 | 4000 | |
| BS*48 | 2400 | 8325 | 122 | 1" | 2" | 8" FLG | 5" FLG | 3" FLG | 48x54 | 345 | 58" | 63" | 70" | 87" | 4600 | 6300 | |
| BS*54 | 3040 | 11598 | 152 | 2" | 10" FLG | 6" FLG | 4" FLG | 54x60 | 500 | 66" | 74" | 76" | 89" | 5600 | 8100 |