SDT/SET Installation & Operation Manual
8Performance Data
Table 8E First Hour Rating 200°F Boiler Loop Water (Universal Sizing, Upper Coil SDT Models)
First Hour Rating - 200°F Boiler Loop Water
(Universal Sizing - 45,000 - 295,000 Btu/hr /
|
| Model |
|
|
|
| SDT065 |
|
|
|
|
|
|
|
|
| SDT080 |
|
|
|
|
|
|
|
| SDT119 |
|
|
|
| ||||
| Boiler Supply Water |
|
|
|
| 200 |
|
|
|
|
|
|
|
|
| 200 |
|
|
|
|
|
|
|
| 200 |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Circulator Flow GPM |
| 5 | 8 |
| 12 | 16 | 20 |
| 5 | 8 |
| 12 | 16 | 20 |
| 5 |
| 8 | 12 | 16 | 20 | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Domestic Outlet | 115 | 140 | 115 | 140 | 115 | 140 | 115 | 140 | 115 | 140 | 115 | 140 | 115 |
| 140 | 115 | 140 | 115 | 140 | 115 | 140 | 115 | 140 | 115 | 140 | 115 | 140 | 115 | 140 | 115 | 140 | ||
|
|
| 45,000 | 117 | 94 | 117 | 94 |
|
|
|
|
|
| 122 | 99 | 122 |
| 99 |
|
|
|
|
|
| 135 | 113 | 135 | 113 |
|
|
|
|
|
|
|
|
| 60,000 | 146 | 115 | 146 | 115 |
|
|
|
|
|
| 151 | 120 | 151 |
| 120 |
|
|
|
|
|
| 164 | 133 | 164 | 133 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Capacity |
| 75,000 | 175 | 137 | 175 | 137 |
|
|
|
|
|
| 180 | 142 | 180 |
| 142 |
|
|
|
|
|
| 192 | 154 | 192 | 154 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 95,000 | 214 | 165 | 214 | 165 | 214 | 165 |
|
|
|
| 206 | 160 | 206 |
| 160 | 206 | 160 |
|
|
|
| 230 | 182 | 230 | 182 | 230 | 182 |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 115,000 | 252 | 193 | 252 | 193 | 252 | 193 | 252 | 193 |
|
| 270 | 208 | 243 |
| 187 | 243 | 187 |
|
|
|
| 268 | 210 | 268 | 210 | 268 | 210 |
|
|
|
|
| Heating |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 140,000 | 265 | 203 | 283 | 216 | 283 | 216 | 283 | 216 | 283 | 216 | 270 | 208 | 286 |
| 220 | 286 | 220 | 286 | 220 |
|
| 315 | 245 | 315 | 245 | 315 | 245 | 315 | 245 |
|
| |
|
|
|
|
|
|
|
| |||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 165,000 | 265 | 203 | 305 | 232 | 328 | 249 | 328 | 249 | 328 | 249 | 270 | 208 | 310 |
| 237 | 333 | 254 | 333 | 254 | 333 | 254 | 357 | 276 | 362 | 279 | 362 | 279 | 362 | 279 | 362 | 279 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Boiler |
| 195,000 | 265 | 203 | 305 | 232 | 334 | 253 | 349 | 265 | 369 | 279 | 270 | 208 | 310 |
| 237 | 339 | 258 | 367 | 279 | 374 | 284 | 357 | 276 | 419 | 321 | 419 | 321 | 419 | 321 | 419 | 321 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 225,000 |
|
| 305 | 232 | 334 | 253 | 349 | 265 | 369 | 279 |
|
| 310 |
| 237 | 339 | 258 | 367 | 279 | 374 | 284 |
|
| 432 | 331 | 475 | 362 | 475 | 362 | 475 | 362 | ||
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 260,000 |
|
|
|
|
|
| 349 | 265 | 369 | 279 |
|
|
|
|
| 339 | 258 | 367 | 279 | 374 | 284 |
|
|
|
| 487 | 372 | 530 | 403 | 542 | 412 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 295,000 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 374 | 284 |
|
|
|
|
|
| 530 | 403 | 602 | 456 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| MAX BTU INPUT | 121786 | 153207 | 168199 | 176783 | 188081 | 121786 | 153207 | 168199 | 176783 | 188081 | 162144 | 202222 | 231672 | 253492 | 291792 | ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Note: Testing conducted with 50°F inlet cold water
24