6Specifications

© Travis Industries 4080728 100-01156

Heating Specifications

Approximate Maximum Heating Capacity (in square feet)*........................................800 to 2,250 Sq. Feet
Burn Rate (Pounds per Hour)**............................................................................1.7 to 5.5
Maximum Burn Time on Low Burn** ......................................................................47 Hours
Hopper Capacity..............................................................................................80 Pounds
* Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside temperature. It is also affected
by the fuel size, quality, and moisture level.
** Small pellets will increase or decrease the stated burn rates and burn times. Differences of plus or minus 20% depending on fuel
quality may occur.

Dimensions

Air Inlet
(1-3/4"
Outside
Diameter)
Weight: 225 Lbs.
4"
Diameter
Exhaust
9-1/4"
16-1/2"
13"
5-1/4"
32"
23"
25"
This tab can be bent
out and used to hang
the scraper rod tool.

Electrical Specifications

Electrical Rating.........................................................................................115 Volts, 3.6 Amps, 60 Hz
Watts During Start-Up Sequence...................................................................400 (approximately)
Watts During Operation...............................................................................180 (approximately)

Fuel

This heater is designed and approved for pelletized wood fuel or a mixture up to 50% corn, 50% pellets.
See page 25 for details on using a corn pellet mix.

EPA Compliance

This heater has been tested exempt from EPA Phase II Requirements by OMNI-Test Laboratories, Inc.