disabled for the stations actually on a call requiring an authorization code, and are reenabled when the dialing of the authorization code is completed or abandoned.

47.When a call covered from an EAS agent login ID extension to a station on another DEFINITY ECS over an ISDN DCS+ trunk, the display at the covered-to station showed the physical station name (rather than the agent’s login ID extension name) where the EAS agent was logged in. Now, the display correctly shows the agent’s login ID extension name.

48.If a user forwarded a station to a remote number for which the length of the number (including an ARS or AAR feature access code) was 16 digits, and the number required an interdigit timeout (typically, an international number, for example, 88+011-44-719710089), the number was accepted. But when a call was forwarded, the system waited indefinitely for the end-of-dialing timeout or a pound sign (#). (Note that a pound sign is stored with the number when the number of digits is less than 16.) Now, Call Forwarding works correctly for any number of digits up to, and including, 16. Call Forwarding cannot store more than 16 digits at present.

49.The calling party on an incoming trunk call that was routed to coverage or a forwarded-to destination off-net did not always hear ringback tone.

50.Some DCS calls were not transparent (they had double burst ringing instead of single burst ringing), meaning that they were treated as external calls.

51.VuStats displays were not updated following an agent login or add/remove skills action until the data displayed changed (the VuStats lamp was on indicating that VuStats was active but the display showed the agent’s skill set rather than the VuStats display).

52.The list configuration command incorrectly displayed circuit pack suffix higher than suffix A for the TN790 and TN798 circuit packs.

53.Calls that used adjunct routing that received AAR analysis in which the value in the Min field did not equal the value in the Max field on the AAR Analysis form, could fail to route out.

54.The list mmi command displayed the cabinet number of the board location to the SAT based on its port network number. On the G3r, these numbers are not always the same.

55.Users of BRI terminals had 127 as a cause value in cases in which a BRI terminal was disconnected. The value of 127 is cause unknown that is really not true because the switch is aware of the Layer 1 status of a data module. Users of a BRI terminal could see some feedback that was somewhat ambiguous. Now, users of BRI terminals have 18 as the cause value that maps to “No User Responding.” On the tested terminals "No Answer" came up as the user feedback at a BRI data terminal. This value is more aligned with the actually physical cause.

Issue 2 May 1998 11

Page 13
Image 13