DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
555-233-115 Issue 1
April 2000
Adding or Removing Cabinet Hardware

6-84Add a Control Carrier (Add Duplication)

6

9. Slide the carrier forward 1 to 2 inches; then , from the back, be sure that no

cables or wiring harnesses are caught on the cab inet/carrier framework.

!CAUTION:
Cables and wiring harn esses can be damag ed if they catch on the framework and if too much p ressure is applied in removing the
carrier.

10. Remove the carrier by sliding it out the front of the cabinet.

Figure 6-28. TDM/LAN Connections for Standard-Reliability PPN

CONTROL CARRIER
SLOT 21
B
A
D
PORT CARRIER
PORT CARRIER
SLOT 21
PORT CARRIER
TDM/LAN BUS
TERMINATOR
SLOT 21
E
(ZAHF4)
SLOT 21
C
REAR VIEW
PORT CARRIER
(ZAHF4)
SLOT 21
J58890AP-1
J58890BB
J58890BB
J58890BB
J58890BB
SEE NOTE
SEE NOTE
SEE NOTE
SEE NOTE
NOTE:
ON PORT CARRIER J58890BB-1, CONNECT THE TDM/LAN CABLE OR TDM/LAN TERMINATOR TO
SLOT 02. ON PORT CARRIERS J58890BB-2 AND -3, CONNECT THE TDM/LAN CABLES TO SLOT 01.
SLOT 01
TDM/LAN BUS TERMINATOR
TDM/LAN CABLE
WP91716 L6
TDM/LAN CABLE
WP91716 L7
TDM/LAN CABLE
WP91716 L6
TDM/LAN CABLE
WP91716 L6