Technical Data
Interfaces
Compliant with the |
|
|
General | G.707 (includes G.708 and G.709) | |
Equipment | G.781, G.782, G.783, G.784, G.813 | |
Physical interface | G.957 & G.691 for optics and G.703 for | |
| electrical interfaces. | |
Performance requirements | G.823, G.825, G.826 | |
Mapping Structure | AU4, | |
| ||
Electrical Interfaces |
|
|
1.5 Mbps | 63 | |
2 Mbps | 63 | (E1) interfaces per circuit pack |
34 / | 12 | |
140 | 4 |
Optical Interfaces
Ethernet 10/100
12 x interfaces per circuit pack | |
4 x | |
| pack |
1 x | |
| pack |
1 x | |
| per circuit pack |
Optical | 1 x |
Optical Booster | 1 x |
OLS 80G (DWDM) interworking | 1 x interface per circuit pack, 16 different |
| wavelengths (1549 - 1559 nm ) |
OLS 400G (DWDM) Interworking | 1x interface per circuit pack, 80 different |
| wavelengths (1530 - 1565 nm ) |
Data interfaces: |
|
Six user selectable datachannels | User can select out of E1, E2, F1, F2 |
| and NU bytes (4xG.703 and 2xV.11) |
Standard External clock interfaces | Two programmable Input/Output |
| station clock interfaces: 2048 kHz |
| (G703.10) or 2048 kbps |
| (G703.6), 75 or 120 W |
Bandwidth Management
System capacity:VC-12: 504 x 1.5 Mbps, 504 x 2 Mbps,
Complete
Higher Order
Lower Order
Broadcast connections type
Higher Order and Lower Order broadcast functionality 1:N (N£9)
Protection access (LPT) on | |
Scalable |
|
Drop & Continue |
|
Performance requirements
Jitter on | G.813, G.825 |
Jitter on PDH interfaces | G.823, G.783 |
Error Performance | G.826 |
Performance monitoring | G.784, G.826 |