Lucent Technologies ADM 16/1 manual Performance Monitorings, Supervision and alarms

Models: ADM 16/1

1 8
Download 8 pages 58.24 Kb
Page 7
Image 7
Performance Monitorings

Performance Monitorings

Trail Termination Points

Equipment

 

VC-12

for each DS1 and E1 port

VC-3

for each DS3, E3 and STM-0 interfaces

VC-4

for each E4 interface and on the Cross-Connect

MS-0

Multiplex Section on the STM-0 interfaces

MS-1

Multiplex Section on the STM-1 interfaces

MS-4

Multiplex Section on the STM-4 interfaces

RS-16

Regenerator Section of the 2.5 Gbps interfaces

MS-16

Multiplex Section of the 2.5 Gbps interfaces

Non-Intrusive Monitoring

on VC-4, VC-3 & VC-12 trails & VC- 4- 4c

Severity setting for alarms

on each TP instance

Enhancements

compliant 24 hr counters Unavailable period storage

History bin:

every 15 minutes (16 bins + 4 hour storage time)

 

Every 24 hours (1 bin + 1 day storage time)

Threshold reports

 

 

Supervision and alarms

 

 

Plug-in circuit pack Indication

 

LED continuously on: diagnostic error

 

 

LED flashing: transmission signal error

System Controller indicators/buttons:

 

LED indicators

 

Power, Prompt and Deferred alarm

 

 

Abnormal, Info, Suppressed, UseCIT,

 

 

and Disconnect

Push-buttons

 

Suppress, Disconnect

CIT connector F-interfaces

 

V.10/RS-232

Station alarm interface outputs

Floating

Miscellaneous Discretes

 

8 inputs and 8 outputs

Q-LAN interface

 

to connect to EMS or other Network

 

 

Elements

Protection and redundancy

Tributary Level Redundancy:

1:N Equipment protection on 1.5 Mbps & 2 Mbps Interface circuit packs (N= max. 8) 1+1 Equipment protection on 34/45 Mbps, 45 Mbps Interface circuit packs

1:N Equipment protection on 140/STM1e (N= max. 4)

1+1 Equipment protection on Cross-connect circuit pack and Power & Timing circuit pack

SNC/N protection:

VC-4 level

VC-12, VC-3 level

Programmable hold-off times

Dual Node Interworking (DNI):

between two MS-SPRings

between MS-SPRing and LO-SNC protected SubNetworks

Support of VC-4-4c Concatenation

MSP:

1+1 MSP on optical STM-0 (G.783 Annex B), STM-1 (G.783 Annex A & B) and STM-4 (G.783 Annex A & B) tributary Interface signals

1+1 MSP on optical Line Interface circuit packs STM-16 (G.783 Annex A)

MS-SPRing:

MS-SPRing in two fiber ring Add/Drop applications

Selective MS-SPRing

Cascading of protection schemes in one Network Element

Programmable hold-off times

Maximum of 50 ms switching time for all protection mechanisms

Page 7