Note: The framed depth, 28 ¹⁄₈" (714 mm) from a framed wall, must always be measured from a finished surface. If a wall covering such as drywall is to be attached to the rear wall, then the framed depth must be measured from the drywall surface. It is important that this dimension be exact.
If the appliance is to be elevated above floor level, a solid continuous platform must be constructed.
The header may rest on the top metal spacers, but must not be notched to fit around them.
Consult all local codes.
FRAMING SPECIFICATIONS
Framing Dimensions
| Model LA41 | |
|
|
|
A | 50 ¹⁄₂" | 1283 mm |
|
|
|
B | 53" | 1346 mm |
|
|
|
C | 34 ⁵⁄₁₆" | 873 mm |
|
|
|
D | 19 ¹⁄₈" | 486 mm |
|
|
|
E | 90 ¹⁄₄" | 2292 mm |
|
|
|
F | 45 ¹⁄₈" | 1146 mm |
|
|
|
G | 28 ¹⁄₈" | 714 mm |
|
|
|
H | 48 ³⁄₈" | 1228 mm |
|
|
|
J | 26 ¹⁄₈" | 664 mm |
|
|
|
K | 63 ¹¹⁄₁₆" | 1622 mm |
|
|
|
Note: All framing dimensions calculated for 1/2" dry wall at the fireplace face. If sheathing the chase or finishing with other thickness materials, calculations will need to be made. False header
Back Wall of Chase/Enclosure | FOAK | |
Including Finising Materials | Combustion | |
if any |
| Air Kit - Optional |
| C |
|
J |
| G |
| A |
|
Rough |
|
|
Framing Face | Outside Chase |
|
(Unfinished Shown) |
| |
Figure 13 |
|
|
Back Wall of |
| FOAK Combustion |
Chase/Enclosure |
| |
| Air Kit - Optional | |
Including Finising |
| |
Materials |
|
|
if any |
|
|
| D |
|
K |
| F |
Header
should be constructed of 2 x material only.
Rough
A
E
False
Header
B
H
A
Fireplace Framing
Figure 11
Back Wall of Chase/Enclosure | FOAK |
Including Finising Materials if any | Combustion |
| Air Kit |
| G |
A | Rough |
| |
| Framing Face |
Inside Chase | (Unfinished |
Shown) |
Figure 12
Framing Dimensions for Ceiling
Flue Type | A | B |
|
|
|
FTF10 Vertical | 19" | 19" |
| (483 mm) | (483 mm) |
|
|
|
FTF10 | 19" | 29" |
Offset 30° | (483 mm) | (737 mm) |
|
|
|
Framing Dimensions for Roof
Pitch | C | D* |
|
|
|
0/12 | 19" | 19" |
| (483 mm) | (483 mm) |
|
|
|
6/12 | 19" | 22" |
| (483 mm) | (559 mm) |
|
|
|
12/12 | 19" | 27" |
| (483 mm) | (686 mm) |
|
|
|
* Perpendicular to roof ridge
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.