2 WIRE 24 VOLT/MILLIVOLT SYSTEM

 

 

 

 

 

SYSTEM COMMON

 

 

RC-RH

 

 

 

 

 

 

JUMPER PROVIDED

W

Y

 

G

B

O

RC

RH

 

C

 

 

 

 

 

 

 

24 VOLT

OPTIONAL

 

HEAT

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAT

 

 

 

 

 

 

 

 

TRANSFORMER

 

 

 

 

 

 

 

 

 

120 VAC

 

 

 

3 WIRE HEATING SYSTEM (3RD WIRE FOR FAN)

 

 

 

 

 

SYSTEM COMMON

 

 

RC-RH

 

W

Y

 

O

RC

JUMPER PROVIDED

 

G

B

RH

 

C

 

 

 

 

 

 

 

24 VOLT

OPTIONAL

HEAT

 

 

FAN

 

 

 

 

 

 

 

 

 

 

HEAT

 

 

 

 

 

 

 

 

TRANSFORMER

 

 

 

 

 

 

 

 

 

120 VAC

 

 

 

 

 

3 WIRE COOLING SYSTEM

RC-RH

 

 

 

 

SYSTEM COMMON

 

 

 

 

 

 

 

 

JUMPER PROVIDED

W

Y

 

G

B

O

RC

RH

 

C

 

 

 

 

 

 

24 VOLT

OPTIONAL

 

AC

 

FAN

 

 

 

 

 

 

 

 

 

COOL

 

 

 

COMPRESSOR

 

 

 

 

 

 

 

TRANSFORMER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120 VAC

 

 

 

WIRING DIAGRAM NOTES (APPLIES TO ALL DRAWINGS)

*Verify whether “C”, “X” or “B” wires are connected to system common.

*If “B” and “O” are both present, it is likely that “B” is a system common.

*If a “B” wire in your system is a common, then connecting it to the “B” terminal may cause damage to your system.

*If “Y” and “C” are both present, it is likely that “C” is a system common.

*Use an optional common wire to allow the system to power your thermostat.

 

4 WIRE HEATING AND COOLING SYSTEM

 

 

 

SYSTEM COMMON

 

 

RC-RH

W

Y

O

RC

JUMPER PROVIDED

G

B

RH

C

 

 

 

 

 

24 VOLT

OPTIONAL

HEAT

AC

FAN

 

 

 

 

 

SYSTEM

 

COMPRESSOR

 

 

 

 

 

 

 

TRANSFORMER

 

 

 

 

 

 

 

 

 

 

120 VAC

 

5 WIRE SYSTEM HEATING AND COOLING - 2 TRANSFORMERS

 

 

SYSTEM COMMON

 

 

RC-RH

W

Y

O

RC

JUMPER REMOVED

G

B

RH

C

 

 

 

 

 

 

 

OPTIONAL

HEAT

COOLING

FAN

 

 

24 VOLT

 

24 VOLT

 

 

COOL

 

HEAT

 

 

 

 

TRANSFORMER

TRANSFORMER

 

 

 

 

 

120 VAC

 

120 VAC

 

SINGLE STAGE HEAT PUMP SYSTEM

RC-RH

 

 

SYSTEM COMMON

 

 

 

 

 

 

JUMPER PROVIDED

W

Y

G

B*

O*

RC

RH

C

ADD

 

 

 

 

 

 

OPTIONAL

JUMPER

 

 

 

 

 

 

 

HEAT

FAN

CHANGEOVER

CHANGEOVER

24 VOLT

 

SYSTEM

 

PUMP

HEAT

 

COOL

 

 

 

 

TRANSFORMER

 

 

 

 

 

 

*"B" OR "O" BUT NEVER BOTH

 

 

 

 

120 VAC

10

 

 

 