INSTALLATION AND
OPERATING INSTRUCTIONS
LUX PRODUCTS CORPORATION | 52022 |
Mt. Laurel, New Jersey 08054, USA
www.luxproducts.com
Please read all instructions carefully. As you complete each step, check the adjoining square ■✓.
■ Disconnect electricity and turn off gas to the heater. |
■ Remove cover from old thermostat. |
■ Disconnect wires from thermostat, making sure they do not fall back inside the wall. |
Make note of wires and to which terminals they are attached as you disconnect |
them. For example: “Yellow wire to terminal Y, Red wire to terminal RH,” etc. |
■ Strip insulation 3⁄8" from wire ends and clean off any corrosion. |
■ Loosen all screws on the old thermostat and remove it from the wall. |
■ Fill wall opening with |
T40-1143SA
HEATING & COOLING THERMOSTAT
ATTENTION : not for use withcompressors without time delays.
50 60 70 80 90
10 15 20 25 30
LUX
| 15 | 20 | 25 |
10 | 60 | 70 | 80 30 |
50 |
|
| 90 |
|
|
|
|
thermostat. |
■ Place new decorative wall plate (if supplied), Figure 4, over wall opening. |
Decorative wall plate can optionally be left off. |
■ Remove Front Cover of new thermostat by inserting a finger in the side of the |
thermostat and gently prying away each corner. Remove Base, Figure 2, from |
■ Place |
mounting holes as shown in Figure 2. Now lay wallplate and |
■ Drill two holes with 3⁄16" bit, 1" deep. |
SPECIFICATIONS
ELECTRICAL RATING24 Vac (30 Vac Maximum)SWITCH ACTIONOpen contact switchANTICIPATOR RATING(HEATING) 0.15A to 1.2A (COOLING) Fixed 24 VAC
TEMPERATURE RANGE50°F to 90°FINSTALLATION & OPERATION
1). THERMOSTAT LOCATIONFor accurate temperature control and comfort, correct location is very important. On new installations, the guidelines listed below should be followed as closely as possible. When replacing an old thermostat, install the new one in the same location unless these conditions suggest otherwise.
1.Locate the thermostat on an inside wall about five feet above the floor, where it is easy to install and adjust. It should be in a room that is used often, such as a family room.
2.Do not install it where there are unusual heating conditions, such as direct sunlight, close to a lamp, radio, television, radiator, register, near a fireplace, or other heat producing appliance. Also, check for hot water pipes within the wall, or a stove on the other side of the wall.
3.Do not locate in unusual cooling conditions, such as on an outside wall, or one separating an unheated room, or in drafts from stairwells, doors, or windows.
4.Do not locate in a damp or humid area. This can shorten thermostat life due to corrosion.
5.Do not locate where air circulation is poor, such as in a corner, alcove, or behind an open door.
6.Do not install until all construction work and painting have been completed.
2) TOOLS REQUIREDWirestripper or knife, drill with 3⁄16" bit, screwdriver, level and a pencil.
■ Insert plastic screw anchors into drilled holes, flush with wall surface. |
■ Bring wires through large hole in decorative wall plate and through Hole For |
Wires in |
■ Referring to your notes and the following diagrams, attach wires to terminal |
screws shown in Figure 2. Make sure bare metal wires do not touch each other. |
Push all excess wire back into wall. |
WIRING DIAGRAMS
|
|
|
|
|
| Heating Systems |
|
| Cooling Systems | ||
FAN RELAY |
|
|
|
|
|
| FAN RELAY |
|
|
| |
| COOLING COMPRESSOR |
|
|
| COOLING COMPRESSOR |
|
| ||||
| HEATING CONTROL |
|
|
| HEATING CONTROL |
|
| ||||
|
| HEATING TRANSFORMER |
|
| HEATING TRANSFORMER |
| |||||
|
|
| DAMPER OR CHANGEOVER VALVE |
| DAMPER OR CHANGEOVER VALVE | ||||||
|
|
|
|
| (POWERED IN HEAT) |
|
| (POWERED IN HEAT) | |||
|
|
|
| DAMPER OR CHANGEOVER VALVE |
| DAMPER OR CHANGEOVER VALVE | |||||
|
|
|
|
|
| (POWERED IN COOL) |
|
| (POWERED IN COOL) | ||
|
|
|
|
|
| COOL TRANSFORMER |
|
| COOL TRANSFORMER | ||
G Y W RH B O RC |
| G Y W RH B O RC |
| ||||||||
Tape Off | Tape Off ** | 4 |
| 5 | Tape Off * |
|
| Tape Off | V |
| |
G |
|
|
|
|
|
| * |
| |||
| H |
| V |
|
| B |
| R |
| ||
| F |
|
| * |
|
| C | C |
| C | |
|
| W | R | RC | RH | G | T | R | |||
| C |
|
|
| Y |
| |||||
C |
|
|
|
|
| F |
|
| |||
T |
|
|
|
|
|
|
|
|
|
|
|
* If replacing a Honeywell | * If both Y and C wire are | ||||||||||
tape off wire “R”; connect wire “B” | present, tape | off “C” wire. | |||||||||
to terminal “RH.” |
|
|
|
|
|
|
|
**If replacing a Honeywell thermostat with a clock wire “C,” tape off wire “C”
|
|
|
| Heating/Cooling Systems |
|
|
| Heating/Cooling Systems | ||||||||||
FAN RELAY |
| 4- or |
|
| 5- or | |||||||||||||
|
|
|
|
|
|
| FAN RELAY |
|
|
|
|
|
|
| ||||
COOLING COMPRESSOR |
|
|
|
| COOLING COMPRESSOR |
|
|
|
|
| ||||||||
| HEATING CONTROL |
|
|
|
|
|
| HEATING CONTROL |
|
|
|
|
| |||||
|
|
| HEATING TRANSFORMER |
|
|
|
|
| HEATING TRANSFORMER |
|
|
| ||||||
|
|
| DAMPER OR CHANGEOVER VALVE |
|
|
|
| DAMPER OR CHANGEOVER VALVE | ||||||||||
|
|
|
|
| (POWERED IN HEAT) |
|
|
|
|
|
|
| (POWERED IN HEAT) |
| ||||
|
|
|
| DAMPER OR CHANGEOVER VALVE |
|
|
|
| DAMPER OR CHANGEOVER VALVE | |||||||||
|
|
|
|
|
| (POWERED IN COOL) |
|
|
|
|
|
| (POWERED IN COOL) | |||||
|
|
|
|
|
| COOL TRANSFORMER |
|
|
|
|
|
| COOL TRANSFORMER | |||||
G Y W RH B O RC |
|
| G Y W RH B O RC |
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| V | R | C |
Tape Off |
|
|
|
|
|
|
|
| Tape Off |
|
|
|
|
|
|
| ||
* |
|
|
|
|
| O |
|
| * |
|
|
|
| O |
| R | ||
|
|
|
|
| B |
|
|
|
|
|
| B |
|
| ||||
F |
|
| V |
|
|
|
|
|
| 4 |
|
|
|
| ||||
Y |
|
|
|
|
| (Optional) | F |
| C |
|
|
|
|
| (Optional) | |||
|
|
|
| R |
| C |
|
|
|
|
| A |
| H |
|
| ||
C | G | C | W | R |
|
| TC | G | Y | W | R |
|
|
| ||||
|
| (Optional) |
|
|
| (Optional) | ||||||||||||
T |
|
|
|
|
|
|
|
|
| |||||||||
* If both Y and C wire are |
|
| * If both Y and C wire are |
| ||||||||||||||
present, tape off “C” wire. |
|
| present, tape off “C” wire. |