OPERATION
SET TEMP
This thermostat is “armchair programmable” You can make any program or setting changes with the thermostat body off or on the wall thermostat base.

OPERATION

The TX1500 alternately displays the current time and the room temperature. It also displays the day of

the week and the currently active program period that is controlling the temperature: MORN, DAY, EVE, or NIght.

The set point temperature will appear in the right side of the display. In the winter, set the system switch to HEAT to control your heating system. In the summer, set the switch to COOL to control your air conditioner. In spring and fall or when windows are open, you can set the system switch OFF.

Setting the FAN switch to AUTO

N

O

T

E

automatically runs your system’s fan

The FAN switch works only if your system

during heating and cooling. Setting the

provides a wire for the TX1500’s “G” terminal.

FAN switch to ON runs your system’s

fan continuously even without heating

 

 

 

 

or cooling.

 

 

 

 

THE BUILT-IN ENERGY STAR® PROGRAMS

VACATION TEMPERATURE HOLD

 

 

 

Press HOLD. Adjust temperature as

 

 

 

 

TU

 

 

desired with UP/DOWN.

 

EVE

HOLD

Temperature setting will not change even

 

 

 

 

 

HEAT

HOLD

after next program period begins.

 

PM

 

To clear, press HOLD again.

 

 

 

 

 

 

 

 

 

 

ADVANCED FEATURES

FILTER USAGE MONITOR

The FILTER Monitor counts the hours since the filter in your blower was last changed. After 250 hours of use, FILTER will appear in the display. After you change the filter, set the thermostat’s FILTER Monitor back to zero as follows.

Rotate the dial

UP

To reset the

 

to FILTER

counter

 

 

HR

 

 

 

FILTER

Push in the RESET key. This sets the built-in heating and cooling programs. To review the built-in programs, rotate the dial to SET WEEKDAY / SATURDAY / SUNDAY PROGRAM.

You can use the built-in programs as shown, or change them as you wish. Each day is divided into four periods. Each period has its own starting time and temperature.

The dial must be in the RUN position to close the door.

 

PERIODHEATCOOL

 

 

 

 

WEEKDAYS

MORN

6:00 AM 70°

6:00 AM 78°

preprograms

DAY

8:00 AM 62°

8:00 AM 85°

 

EVE

6:00 PM 70°

6:00 PM 78°

 

NIGHT

10:00 PM 62°

10:00 PM 82°

 

 

 

 

 

MORN

6:00 AM 70°

6:00 AM 78°

SAT & SUN

DAY

8:00 AM 62°

8:00 AM 85°

preprograms

EVE

6:00 PM 70°

6:00 PM 78°

 

NIGHT

10:00 PM 62°

10:00 PM 82°

To change the FILTER Usage Monitor limit

 

 

Rotate the dial to FILTER

 

 

 

 

 

Hold for two

 

DOWN

To change the

SET

NEXT

UP

 

 

seconds

 

 

limit from

HR

 

 

 

 

 

 

 

 

0-500 hours

FILTER

 

 

 

 

 

To disable the FILTER Usage Monitor set the limit to 0 hours

TEMPERATURE SWING

A thermostat works by turning your heating or cooling system on and off whenever the room temperature varies a certain number of degrees from the set-point temperature. This variation is the “swing.”

PROGRAMMING THE TX1500

You can change any preset times and/or temperatures to suit your schedules for the weekday, Saturday and Sunday programs. Each period (Morning,

Day, Evening, and Night) is programmed for HEAT and for COOL. PROGRAM MO TU WE TH FR

FOR: MORN

 

 

 

START AT:

 

 

 

HEAT

 

 

 

AM

HEAT

 

 

 

OFF

Select HEAT to program the

OR

Select COOL to program the

COOL

TX1500 for controlling your heater.

 

TX1500 for controlling your air conditioner.

 

 

Rotate dial to SET WEEKDAY PROGRAM. To program SATURDAY or SUNDAY, rotate the dial to SET SATURDAY or SET SUNDAY PROGRAM. With dial on SET WEEKDAY PROGRAM, you will see the display above.

 

UP

DOWN To change the start

 

UP

DOWN To change the start

 

 

 

time for MORN.

 

 

 

 

time for EVE.

 

NEXT

To program temperature.

 

NEXT

To program temperature.

 

UP

DOWN To change the temp.

 

UP

DOWN To change the temp.

 

 

 

setting for MORN.

 

 

 

 

setting for EVE.

 

NEXT

To move to DAY.

 

NEXT

To move to NIGHT.

 

 

UP

DOWN To change start time

 

UP

DOWN To change the start

 

 

 

for DAY.

 

 

 

 

time for NIGHT.

 

NEXT

To program temperature.

 

NEXT

To program temperature.

 

UP

DOWN To change the temp.

 

UP

DOWN To change the temp.

 

 

 

setting for DAY.

 

 

 

 

setting for NIGHT.

 

NEXT

To move to EVE.

 

Rotate dial to RUN position to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

start the programs.

 

SETTING THE TIME AND DAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SU

 

 

 

C

A

U

T

I

O

N

 

 

 

 

 

DAY

 

 

 

The TX1500 is protected against normal static electric discharges.

 

 

 

 

 

 

PM

 

 

 

However, in extremely dry weather you should touch another metal object

 

 

 

 

 

before the TX1500 to avoid potential loss of programs.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open the drop down door on the front of the thermostat. Rotate the dial to the SET DAY/TIME position. You should see the display pictured above with a day of the week flashing. When you are finished setting the day and time, rotate the dial to RUN to return to normal operation or to another position to continue programming.

 

UP To change

 

NEXT

To set current time. The (e.g.

UP

To change the

 

 

 

 

current day.

 

 

“12:00”) will be flashing.

DOWN

current time.

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE OVERRIDE AND

These features let you change the current Set

TEMPERATURE HOLD

 

Temperature without changing the programs stored

 

in your thermostat’s memory.

 

 

 

 

 

 

 

 

TEMPORARY

 

 

 

• Press UP/DOWN to change the current temperature

TEMPERATURE OVERRIDE

setting. The OVERRIDE indicator appears on display.

 

 

 

 

 

• The OVERRIDE feature will be automatically canceled

 

TU

 

 

UP

at the start of the next program period.

 

 

EVE

OVERRIDE

 

 

• To cancel OVERRIDE prior to next program period press

 

 

 

 

 

 

 

 

HEAT

DOWN

UP/DOWN until original set temperature

 

PM

 

 

appears. OVERRIDE indicator will disappear from display.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Your system should cycle on about 3 to 6 times per hour. A smaller swing number increases the number of cycles, so room temperature is more constant. A larger swing number decreases the number of cycles, to save energy in most cases.

SWING SETTINGS

 

 

HOLD

NEXT

Press together

 

SET TEMP SWING

Dial must be in

 

 

 

To change

 

 

the run position

UP

DOWN

 

 

 

 

 

 

swing

 

 

 

 

 

 

 

 

 

 

 

NEXT

Press to set.
TEMPERATURE CALIBRATION

 

 

 

Press together

 

 

 

 

HOLD

NEXT

 

 

 

Rotate the dial to

UP

DOWN

 

To adjust the

 

 

SET DAY/TIME

 

 

 

 

 

 

thermostat

 

 

 

 

 

 

 

PROGRAM LOCK

 

 

 

 

 

 

To prevent tampering with set programs.

 

MORN

 

TH

 

 

 

The sequence of keys to lock and unlock the program:

 

 

 

HEAT

 

 

 

 

 

 

 

 

 

 

 

 

AM

 

 

NEXT

NEXT

NEXT

HOLD

 

 

 

 

W

A

R

N

I

 

N

G

Making these changes will require you to reset the thermostat. Copy any of your customized programs onto the blank chart. This will be your reference to re-enter the programs afterwards.

CHANGING FROM °F TO °C AND A 12HR CLOCK TO A 24HR CLOCK

WARNING: Making these changes will require you to reset the thermostat.

Located to the right of the gas electric switch are two black jumpers C/F and 24/12H.

To change to Celsius - remove jumper - C/F.

• To change to a 24HR clock - remove jumper- 24/12H.

 

 

 

SW1

Press the reset key on the front of the thermostat for

ELECT

 

 

 

 

GAS

 

 

 

 

 

 

RL1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5/2 MIN C/F 24/12H

 

changes to take effect.

 

 

 

 

 

 

ON/OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reprogram as necessary.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 MIN/2 MIN MINIMUM ON/OFF TIME

Your thermostat has an internal timer built in to protect your compressor. The timer forces a minimum on/off time of 5 minutes. You may change this minimum on/off time to 2 minutes. To accomplish this, remove the jumper labeled 5/2 MIN. You must press the small reset button on the face of the thermostat for the changes to take effect.

Page 3
Image 3
Lux Products TX1500 Operation, Advanced Features, The Built-In Energy Star Programs, Filter Usage Monitor, Program Lock