Do not allow wires to touch each other or parts on thermostat. Wires must be trapped between black spacer and brass terminal. Also, be sure to tighten securely all 7 electrical terminal screws.
WIRING DIAGRAMS
| | | | | | | | | | | Heating Systems | | | | | | | | | | | | | | Cooling Systems |
FAN RELAY | | | | | | | | | | | FAN RELAY | | | | | | | | | | | | |
| | COOLING COMPRESSOR | | | | | | | | | COOLING COMPRESSOR | | | | | | | |
| | | | | | | | | | | | | | | | |
| | | | HEATING CONTROL | | | | | | | | | | | HEATING CONTROL | | | | | | | |
| | | | | | HEATING TRANSFORMER | | | | | | | | | HEATING TRANSFORMER | | | | | |
| | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | |
| | | | | | | DAMPER OR CHANGEOVER VALVE | | | | | | | | | DAMPER OR CHANGEOVER VALVE |
| | | | | | | | | | | | | | |
| | | | | | | | | | (POWERED IN HEAT) | | | | | | | | | | | | | | (POWERED IN HEAT) | | |
| | | | | | | | | DAMPER OR CHANGEOVER VALVE | | | | | | | | | | | DAMPER OR CHANGEOVER VALVE |
| | | | | | | | | | | (POWERED IN COOL) | | | | | | | | | | | | | | (POWERED IN COOL) |
| | | | | | | | | | | COOL TRANSFORMER | | | | | | | | | | | | | | COOL TRANSFORMER |
| G Y W RH B O RC | | | | | G Y W RH B O RC | | | | | |
| | | | | | | | | Tape Off * | | | | | | | | | | | | | | | | | | | | | |
Tape Off | Tape Off ** | 4 | | 5 | | | | | | | | | | | Tape Off | | | V | | | | | |
G | | | | | | | | | | | | | | | | * | | | | | | | | | | | |
| | | | H | | V | | | | B | | | | | | | | | | | | | | | R | | | | |
| | F | | | * | | | | | | | | | | C | | C | | | | | | C | | |
| | | | | W | | R | C | | | | | | | | G | | | | | T | | | | | | R | | |
| | | | | | | | R | H | | | | | | | Y | | | | | | | | | | | |
| TC | | C | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | R | | | | | | | F | | | | | | | | | | | | | | | |
* If replacing a Honeywell TM-11, | * If both Y and C wire are | | | | | |
tape off wire “R”; connect wire “B” | | present, tape | | off | “C” wire. | | | | |
to terminal “RH.” | | | | | | * If you have a “B” wire in your system which |
** If replacing a Honeywell thermostat | is used as a common wire, connecting it to |
with a clock wire “C,” tape off wire “C” | the “B” terminal on this thermostat may |
| | | | | | | | | | | | | | | damage your system and/or the thermostat. |
| | | | | | | | | | | | | | | | |
| | | | | | | Heating/Cooling Systems | | | | | | | | Heating/Cooling Systems |
FAN RELAY | 4- or 5-Wire with One Transformer | | | | | | 5- or 6-Wire with Two Transformers |
| | | | | | | | | | FAN RELAY | | | | | | | | | | | | |
| | COOLING COMPRESSOR | | | | | | | | | COOLING COMPRESSOR | | | | | | | |
| | | | | | | | | | | | | | | | |
| | | | HEATING CONTROL | | | | | | | | | | | HEATING CONTROL | | | | | | | |
| | | | | | HEATING TRANSFORMER | | | | | | | | | | HEATING TRANSFORMER | | | | | |
| | | | | | | | | | | | | | | | | | | |
| | | | | | | DAMPER OR CHANGEOVER VALVE | | | | | | | | | | DAMPER OR CHANGEOVER VALVE |
| | | | | | | | | | | | | | | |
| | | | | | | | | | (POWERED IN HEAT) | | | | | | | | | | | | | | | (POWERED IN HEAT) | | |
| | | | | | | | | DAMPER OR CHANGEOVER VALVE | | | | | | | | | | | DAMPER OR CHANGEOVER VALVE |
| | | | | | | | | | | (POWERED IN COOL) | | | | | | | | | | | | | | (POWERED IN COOL) |
| | | | | | | | | | | COOL TRANSFORMER | | | | | | | | | | | | | | COOL TRANSFORMER |
G Y W RH B O RC | | | | | G Y W RH B O RC | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | V | | R | C |
Tape Off | | | | | | | | | | | | | | Tape Off | | | | | | | | | | | | | | |
| | * | | | | | | | | O | | | | | * | | | | | | | | | | O | | | R |
| | | | | | | | | | B | | | | | | | | | | | | | | | B | | | | |
| | F | | | | V | | | | | | | | | | | | | 4 | | | | | | | |
| | Y | | | | | | | (Optional) | | | | F | C | | | | | | | | | (Optional) |
| | | | | | | | | R | C | | | | | | | | | | | | | | A | | | H | | | |
C | G | | C | | W | | | | | | | TC | G | | Y | W | | | R | | | | | |
| | | | | | | (Optional) | | | | | | | | (Optional) |
T | | | | | | | | | | | | | | | | | | | | | |
* If both Y and C wire are | | | | | | | * If both Y and C wire are | | |
present, tape off “C” wire. | | | | | | | present, tape off “C” wire. |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
These diagrams below are provided for new installations or unreferenced wires.
N O T E
If you have an electric system and the blower does not operate after installation, find the electric/gas heat selector on the back of the body. Move the selector to the ELEC position.
INSTALLING BATTERIES/ MAINTENANCE
The TX1500 requires batteries to operate your furnace and retain its programming in memory and to light the display. Replace the batteries when the REPLACE indicator appears in the display or at least once a year.
| N | O | T | E |
| When replacing batteries, you have approximately 1 |
REPLACE | minute before programs are lost. |
REPLACE BATTERIES WHEN | | | | | | | | |
Heat Selector | | | | | | | | | |
INDICATOR APPEARS | | | | | SW1 |
OR AT LEAST | | | ELECT | | | GAS | | | |
ONCE A YEAR. | | | | | | | | | | |
| | RL1 | | | | | | |
| | | | | | | 5/2 MIN C/F 24/12H |
| | | | | | | ON/OFF |
1. Remove fresh batteries from their carton.
2. Remove body of thermostat as described at bottom of first column.
3. Remove the used batteries.
4. Install two new Energizer® or DURACELL® "AA" size | Battery |
alkaline batteries in the battery compartment. | Compartment |
Observe the polarity marking shown in the | |
compartment. Place body back on wall. | |
WARNING: Use Energizer® or DURACELL®
Alkaline Batteries Only.
5.Hook the top of the body onto the base, swing the body down and snap the body onto the base.
Installation is now complete. Be sure to turn the power back on to your heating and /or air conditioning system. If this is the first time you are installing batteries, the thermostat will display “SUN 12:00 AM”. Within 90 seconds the thermostat will begin to display the room temperature alternately with the time. To correct the display, see “Setting the TIME and DAY,” after you set the programs.
TECHNICAL SERVICE
If you have any problems installing or using this thermostat, please carefully and thoroughly review the instruction manual. If you require assistance, please contact our Technical Assistance Department at 856-234-8803 during regular business hours between 8:00AM and 4:30PM Eastern Standard Time, Monday through Friday. You can also receive technical assistance online anytime day or night at http://www.luxproducts.com. Our web site offers you answers to the most common technical questions, and also permits you to email your questions to our technical support staff at your convenience.
WARRANTY
Limited Warranty: If this unit fails because of defects in materials or workmanship within three years of date of original purchase, LUX Products Corporation will, at its option, repair or replace it. This warranty does not cover damage by accident, misuse, or failure to follow installation instructions. Implied warranties are limited in duration to three years from date of original purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Please return malfunctioning or defective units to the participating retailer from which purchase was made, along with proof of purchase. Please refer to "TECHNICAL ASSISTANCE" before returning thermostat. Purchaser assumes all risks and liability for incidental and consequential damage resulting from installation and use of this unit. Some states do not allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Applicable in the U.S.A. only.