POWER OUTPUTS

Connect the appropriate POWER OUTPUT voltage terminal to the "+" (HIGH) leg and the "0" terminal to the "–" (LOW) leg of the distributed speaker system.

INPUT The ground (COMMANDS) terminal is internally connected to the chassis and safety ground on the AC linecord.

Manual background The PRIORITY terminal activates the priority function for the BALANCED IN by using an external normally-open switch to short-circuit the PRIORITY terminal to the GND Manual background (ground) terminal. When the PRIORITY function is enabled, the UNBALANCED IN is muted (no signal from the UNBALANCED IN is transmitted to the outputs).

Manual background This GND terminal is the common connection point for BALANCED IN and PRIORITY.

Manual background The BALANCED IN terminals are the main input for the amplifier and accept a balanced line-level signal (0 dBu nominal). This input has a priority function, which mutes the UNBALANCED IN signal when the PRIORITY terminal is shorted to GND.

Manual background The STAND BY terminal is used to turn on the amplifier with a remote switch.

Note: Standby mode must first be activated by moving a jumper (J1) on the input board (standby mode is disabled by default). See "Internal Settings" on page 8.

When the POWER switch is turned on, the amplifier goes into standby mode. In this state, the amplifier is on but signal is not allowed to pass. Shorting the STAND BY terminal to the GND Manual background terminal with an external switch causes the amplifier to become fully operational.

Manual background The STANDBY GND terminal on the COMMANDS terminal strip is the common connection point for STAND BY.

Manual background The OVERL. 300mA terminal is active whenever the amplifier's overload protection circuit is activated. This provides 18 VDC with a maximum output capacity of 300mA for driving an auxiliary relay or indicating LED.

Manual background The OVERL. GND terminal on the COMMANDS terminal strip is the common connection point for OVERL. 300mA.

Manual background AC Protection Fuse protects the power supply and amplifier circuitry. Replace only with same type fuse.

Manual background Connect the supplied AC linecord to the IEC AC Socket. The AC line fuse is contained in the socket, behind the cover located at the bottom of the socket. Replace only with same type fuse.

Manual background The VOLTAGE SELECTOR switch is used to select the AC supply voltage for the amplifier. Move the switch so the AC line voltage used appears on the switch (DOWN for 115V, UP for 230V).

Manual background The H.P. switch activates a high-pass filter on the balanced and unbalanced inputs, which attenuates frequencies below 300Hz at 12 dB/octave.

Manual background The L.P. switch activates a low-pass filter on the balanced and unbalanced inputs, which attenuates frequencies above 7kHz at 12 dB/octave.

Manual background UNBALANCED IN is an RCA jack that can be used instead of the BALANCED IN, or both can be used with the PRIORITY function, which gives the BALANCED IN priority over the UNBALANCED IN.

Manual background PARALLEL OUT is an RCA jack that is in parallel with the UNBALANCED IN jack for connecting to the input of another power amplifier.

Manual background The SENSITIVITY switch adjusts the input sensitivity of the UNBALANCED IN from 0 dB (typical line-level signals) to 20 dB (for low-level signals).

+

POWER INPUT

D.C. FUSE

24V D.C.

-

115

VOLTAGE

 

 

SELECTOR

LINE

 

50/60 Hz-115/230V

 

POWER OUTPUTS

POWER OUTPUTS

INPUT

COMMANDS

0

50V

70V

100V

0

4

25V

PRIORITY

GND

STAND

GND OVERL. GND

 

 

 

 

 

 

 

 

 

BY

300mA.

 

 

 

 

 

 

 

 

BALANCED

 

max

 

 

 

 

 

 

 

 

IN

 

 

 

 

 

 

 

 

 

 

FILTER

 

PARALLEL OUT

CAUTION

 

WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT

 

SERIAL NUMBER

MANUFACTURING DATE

 

 

 

 

 

 

 

 

 

 

EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. DO NOT REMOVE COVER.

 

 

 

 

H.P.

L.P.

 

RISK OF ELECTRIC SHOCK

 

NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.

 

 

 

 

 

DO NOT OPEN

 

AVIS: RISQUE DE CHOC ELECTRIQUE — NE PAS OUVRIR

 

 

 

 

 

 

UNBALANCED IN

 

 

 

 

 

 

 

 

 

REPLACE WITH THE SAME TYPE FUSE AND RATING.

UTILISE UN FUSIBLE DE RECHANGE DE MÊME TYPE.

 

 

 

 

DISCONNECT SUPPLY CORD BEFORE CHANGING FUSE

DEBRANCHER AVANT DE REMPLACER LE FUSIBLE

 

 

 

 

CONCEIVED, DESIGNED, AND MANUFACTURED BY MACKIE INDUSTRIAL • MADE IN ITALY • PATENTS PENDING • COPYRIGHT ©1999

 

 

 

OFF

 

 

 

THE FOLLOWING ARE TRADEMARKS/REGISTERED TRADEMARKS OF MACKIE DESIGN INC.: "MACKIE", "MACKIE INDUSTRIAL", & THE "RUNNING MAN" FIGURE

ON

 

SENSITIVITY

20dB

Manual background 0dB

UP4000 – 5

Page 5
Image 5
Mackie UP4061, UP4161, UP4121 instruction manual Power Outputs, Input, Commands