Madrigal Imaging BPA 2, BPA 3 manual 100V to 120VAC

Models: BPA 3 BPA 2

1 22
Download 22 pages 37.56 Kb
Page 14
Image 14
100V to 120VAC

Remote turn-on tip polarity

Caution!

Caution!

Your Proceed dealer can help you take advantage of these design features to maximize your system’s versatility.

3AC MAINS FUSE

One fast-blow fuse is located on the rear panel of the BPA. If it should be- come necessary, replace the fuse with the same type only. Refer to the fol- lowing table for replacement values.

 

BPA 2

BPA 3

100V to 120VAC

8 amp

12 amp

200V to 240VAC

4 amp

6 amp

ALWAYS remove the AC cord before removing the fuse!

4SPEAKER BINDING POSTS

The Proceed BPA is equipped with gold-plated, high-current binding posts for output termination to a loudspeaker system. To take full advantage of the AMP’s sonic quality, we recommend using high-quality speaker cable; we suggest you see your Proceed dealer for specific recommendations.

NEVER connect the Proceed BPA output terminals to any device other than a loudspeaker.

NEVER short-circuit the amplifier’s output terminals.

NEVER connect the left-channel output terminals to the right- channel output terminals.

There are two recommended methods for connecting speaker cables to the Proceed BPA. A high-quality spade lug or hook lug, soldered to the cable (or crimped with extremely high pressure, or both) is best.

Connect the left-channel + (positive or red) output post of the Proceed BPA to the + (positive or red) input terminal of the appropriate loudspeaker.

Connect the left-channel (negative or black) output post of the BPA to the

(negative or black) input terminal of the appropriate loudspeaker. Repeat this procedure for the remaining channel(s).

14

Page 14
Image 14
Madrigal Imaging BPA 2, BPA 3 manual 100V to 120VAC