RMB 600 Series -S Models with safety pilot

1.Turn all burners to OFF.

2.Remove the top grid.

3.Remove a radiant.

4.Turn the shut off valve to ON.

5.Press and hold the reset (blue) button on the safety pilot valve. Wait 15–30 seconds. Light the runner tube. DO NOT release the reset button.

NOTE: If the runner tube does not light, wait a few seconds, then try again.

NOTE: When lighting the runner tube for the first time after connecting the unit to the gas source, the light time will probably increase to 1–2 minutes.

6.Wait an additional 15–30 seconds. Release the reset button. The runner tube should remain lit.

NOTE: If the runner tube fails to ignite, repeat step 5. If the runner tube fails to ignite after three attempts, contact an authorized MagiKitch’n service agent.

7.Replace the radiant and top grid.

8.Push and turn the burner valves to operate the individual burners as needed.

Broiler Shut Down

1.Turn the shut off valve to OFF.

2.Turn all burners to OFF.

 

Off

Shut-off

 

Valve

Top Grid

On

 

Radiant

Runner Tube

Reset Button

Safety Pilot Valve

Thermocouple

(located on far

end of runner tube)

Safety Pilot Valve (located under

shelf)

SMB 600 Series -S Models with safety pilot

Lighting and shut down of these models is identical to that of the RMB-S models except that there are no radiants to be removed. Simply light the runner tube by inserting the ignition device through the gap between the front burner support and the coal support as shown in the lighting instructions for the SMB 600 Series Models without safety pilot.

L25-001 REV 1 (11/02)

Page 8
Image 8
Magikitch'n 600 SERIES manual RMB 600 Series -S Models with safety pilot, SMB 600 Series -S Models with safety pilot