ALA200FKE Primary Feature Operation

ALA200FKE Primary Feature Operation

Other than arming and disarming your security system, the ALA200FKE has a host of features that enhance ownership and the level of security provided by the ALA200FKE system. Please take a moment to become familiar with the operation of these features as you may need to use them at some point in time. To practice operating these features, repeat the enclosed procedure for each feature as it is written or illustrated.

System Override/Valet

A patented removable switch is used to override the security system in the event that the transmitters are lost or fail to operate and to put the security system in non-operational mode (valet) for vehicle servicing etc.

Note: The removable valet switch can only be inserted into the valet switch housing one way. Do not force the switch or bend the switch terminals.

Override Operation (security system is armed)

1.Enter the vehicle, the security systems will begin sounding at this point, and place the override switch into the switch housing. Make sure that the switch button is in the OUT position.

2.Place the ignition key into the ignition switch and turn the ignition switch to the ON position.

3.Within 5 seconds of turning the ignition key ON, press the valet switch button IN until it locks.

4.The vehicle horn will stop sounding.

5.The LED indicator will be solid red.

The security system is overridden and is now in the Valet Mode.

Valet Operation (security system is already disarmed)

1.Place the valet switch into the switch holder making sure that the switch button is in the OFF position (switch button is out).

2.Turn the ignition key to the ON position.

3.Within 5 seconds of turning the ignition key ON, push IN the valet switch.

4.The LED will be on solid indicating that the security system is in the Valet Mode.

Note 1: If the valet switch is already in the ON position when you turn ON the ignition key, the valet function will be bypassed. Turn OFF the ignition key, set the switch to the OFF position and try again. Note 2: If you fail to push IN the valet switch within 5 seconds of turning ON the ignition key, the valet function will be locked out. Turn OFF the ignition key, set the switch to the OFF position and try again.

Starter Disable (Optional Feature)

If your Silencer security system has been installed with the optional starter interrupt relay, This relay will break the connection between your ignition key and the starter on your vehicle. To test this feature, repeat the following procedure:

1.Enter the vehicle and close all the entrances.

2.Press the LOCK button on the transmitter.

3.Turn the ignition key to the start position. The engine will not crank over.

4.Turn the ignition key to the OFF position and press the UNLOCK button on the transmitter.

5.Turn the ignition key back to the START position and the engine will crank over and start.

Built-In Dual Zone Shock/ Impact Detector

Your SIlencer ALA200FKE has a built-in “Dual Zone” type shock detector. At all times when your system is armed, the built-in shock sensor will detect intrusion attempts at two levels.

Level 1: Light impacts to your vehicle at a non-threatening level will cause the built-in internal beeper to beep 3 times. These three beeps are a pre-warning message to a would-be thief.

Level 2: Heavy impacts to your vehicle such as breaking a window or breaking out the door lock cylinder will cause a full alarm condition and the vehicle horn will start honking.