Installation

UVSRC Series Fireboxes

Installation

Planning

In planning the installation for the firebox it is necessary to determine where the unit is to be installed and whether optional accessories are desired. Gas supply piping should also be planned.

These models MAY NOT be installed in OEM mobile homes.

These models MAY BE installed in a bedroom provided the logset installed in the unit is certified and rated at 10,000 BTU's or less.

These models MAY NOT be installed in a bathroom.

Glass doors are NOT to be used on these fireboxes.

The firebox can be mounted on any of the following surfaces:

A flat hard combustible surface.

A raised platform of combustible or non-combus- tible material.

A concrete block or other solid object placed beneath each of the four corners of the appli- ance.

If the firebox is installed directly on carpeting, tile or other combustible material other than wood flooring, it should be installed on a metal or wood panel extending the full width and depth of the unit.

At this point, you should have decided what compo- nents to include in your installation, and where the firebox is to be located. If this has not been done, stop and consult your dealer for assistance with this plan- ning.

Framing

Firebox framing can be built before or after the firebox is set in place. Framing should be positioned to accom- modate wall covering and firebox facing material. The firebox framing should be constructed of 2 x 4 or heavier lumber. The framing headers may rest on the top of the firebox standoffs. Refer to Figures 1 & 2 for firebox framing dimensions.

Anchor Firebox Into Position

To prevent shifting of the firebox and to maintain sealing (described later), anchor the firebox.

Use the four fastening tabs provided with the firebox and nails or other suitable fasteners to secure the firebox to vertical framing members. (Fig. 5)

Top

Standoff

Nail Side-

Nailing

Flanges

FP606a

Fig. 5 Fasten firebox in position using the nailing flanges.

Installing Outside Air Kit

An outside air kit may be installed in all UVSRC Series fireboxes. If desired, or if local codes mandate the use of an air kit, then an AKU1 is required to complete the installation (from air kit to the outdoors). If the outside air kit is to be used, the AKU1 MUST be installed BEFORE the fireplace is enclosed. Refer to the AKU1 instructions for field installation.

Connect the Gas Line

Gas access holes are provided on both sides of the firebox.

Check gas valve type. Use only the gas type indicated on the gas log rating plate. If the gas listed on the plate is not your type of gas supply, DO NOT INSTALL.

Contact your Dealer for proper model.

Always use an external regulator for all LP fireboxes to reduce the supply tank pressure to a maximum of 14" w.c. This is in addition to the regulator fitted to the vent- free heater.

WARNING: CONNECTION DIRECTLY TO AN UNREGULATED LP TANK CAN CAUSE AN EXPLOSION.

For final connection of the gas log heater to the gas line see Section 5 and Figure 6.