UVSRC Series Fireboxes
Install Hood
A hood is furnished with the firebox. Optional hoods listed on Page 12 may be installed as shown in Figures 16 and 17. Failure to do so may create a fire hazard.
WARNING: When the black surround is covered by a brick surface, (Figure 16), use an extended hood. The hood should extend out to the brick surface (Figures 16 and 17) and be attached to the firebox. The maximum brick to noncombustible surface that may extend out past the black surround surface is 4¹⁄₄".
Maintenance
Keep the control compartment, logs and burner area surrounding the logs clean by carefully vacuuming or brushing at least twice a year or as necessary.
THE LOGS CAN GET VERY HOT — HANDLE ONLY WHEN COOL.
Always turn off the gas to the pilot before cleaning. For relighting, refer to the lighting instructions located on the Rating Plate of the gas log set.
Never obstruct the flow of combustion and ventilation air. Keep the front of the appliance clear of all obstacles and materials.
Leave at least a 36" clearance from the front of the firebox to any room furnishings.
4¹⁄₄" Max.
Brick Surface
Extended Hood
| FP612a |
Fig. 16 | Side view of firebox with extended hood. |
| Top of Fireplace |
| Surround |
| Slot |
Screw |
|
(Fastens to side rail | |
from inside hood) | |
Use | |
Bottom | |
Slot | |
| Screw |
| FP613a |
Fig. 17 | Hood location. |
10 | 20002068 |