6
After adjusting the positive stops, set the blade at 90° to
the table surface. Then adjust the arrow pointer so that
its right edge is aligned to the 0° graduation.
Switch actionCAUTION:
•Before plugging in the tool, always be sure that the
tool is switched off.
To start the tool, raise the switch lever. To stop it, lower
the switch lever.
The hinged switch lever plate can be locked by passing
padlock through the hasp on the left hand side.
Sub table (R)This tool is provided with the sub table (R) on the right
side of the main table. To use the sub table (R), raise
both levers on the front right side, pull out the table (R)
fully and then lower the levers to secure it.
When using the sub table (R ), locate the scale plate on
the sub table after loosening the screw on it with a screw-
driver so that it becomes successive with the scale plate
on the main table.
Sub table (back) and sub table (L) (BOTH optional accessories)NOTE:
•When using the sub table (back ) during use of the
rip fence, pull out the sub table (back) more than 50
mm so that it does not hit against the top end of the
rip fence.
1. Arrow pointer
1. Switch
1. Padlock
1. Lever
1
006158
ON OFF
1
006217
1
006216
1
006149
1. Sub table (R)
1. Scale plate
2. Screw
1. Sub table (back)
2. Screw
1
006150
1
2
006162
1
2
006212