For No. 1 method, set the change lever to the “Intermittent Nailing” position.

For No. 2 method, set the change lever to the “Continuous Nailing” position. After using the change lever to change the nailing method, always make sure that the change lever is properly set to the position for the desired nailing method.

CAUTION:

Operating the tool without nails shortens the life of the tool and should be avoided.

Air exhaust

Air exhaust direction can be changed easily by rotating the exhaust cover. Change it when necessary.

tcover

I

Jammed nailer

CAUTION:

Always lock the trigger, disconnect the hose and remove the nails from the magazine before cleaning a jam.

When the nailer becomes jammed, proceed as follows: Open the door and magazine cap and remove the nail coil. Insert a small rod or the like into the ejection port and tap it with a hammer to drive out the nail jamming the ejection port. Reset the nail coil and close the magazine cap and door.

Hook

The hook is convenient for hanging the tool temporarily. This hook can be installed on either side of the tool.

CAUTION:

*Always lock the trigger and disconnect the hose when hanging the tool using the hook.

*Always tighten the hook securing bolt firmly. Loose bolt may cause air leakage from the tool.

14

Page 14
Image 14
Makita AN901 instruction manual Air exhaust, Jammed nailer, Hook