P 8/ 9
Wiring diagram
Fig. | Fig. |
Lead Wires of Brush Holder
Fix Lead wires with Lead wire holders on Yoke unit side.
Line Filter and Brush holders’ Lead wires
•Line filter’s position has to be adjusted that it distances max. 30 mm from the rib for Yoke unit.
•Two lead wires from Brush holder have to be coiled around Line filter one turn.
Lead wire holders
Yoke unit side | Line filter |
(if used) |
Brush holder | max. |
| 30 mm |
Lead wire (black) of Brush holder
Lead wire (red) of Brush holder
Line filter (if used)
Fig. D-4
Rib for Yoke unit
Lead wire holder
Line Filter (if used)
Put Line filter between
Lead wire holder and
Controller.
Controller
Motor Housing
Fix Lead wires in these Lead wire holders.
Line Filter (if used)
•Lead wires (black, red) to Insulated connector have to be passed through Line filter.
•Slack portion of lead wires have
| to be stored in this place. |
Brush holder | Fix Lead wires in |
| |
| these Lead wire holders. |
Front grip switch
Put Insulated connectors in this place.