2"

Metal Safety Strips

 

with 1" Overlap

Figure 8

Platform

FIREPLACE SPECIFICATIONS

15"

8⁹⁄₁₆"

48"

45 ¹⁄₈"

28"

8⁹⁄₁₆"

59 ³⁄₈"

Front

2"

Special “Z” Metal Safety

 

Strips with 1" Overlap

Figure 9

IMPORTANT: UNDER NO CIRCUMSTANCES CAN THE FIREPLACE TOP SPACERS (FIGURE 10 ) BE REMOVED OR MODIFIED, NOR MAY YOU NOTCH THE HEADER TO FIT AROUND OR BE INSTALLED LOWER THAN THE SPACERS. THE HEADER MAY BE IN DIRECT CONTACT WITH THE TOP SPACERS BUT MAY NOT BE SUPPORTED BY THEM.

Note: The framed depth, 29 ³⁄₄" (755 mm) from a framed wall, must always be measured from a finished surface. If a wall covering such as drywall is to be attached to the rear wall, then the framed depth must be measured from the drywall surface. It is important that this dimension be exact.

14 ¹ ₄"

1"

53 ¹⁄₄"

Gas

Line Access

13 ³⁄₄"

10"

30 ³⁄₈"

Left Side

14 ¹ ₄"

1"

53¹⁄₄"

 

 

Combustion

 

11 ⁵⁄₈"

 

Air Access

 

 

 

 

11 ¹⁄₈"

³⁄₄"

Gas Line

10"

13

Access

30 ³⁄₈"

Right Side

If the appliance is to be elevated above floor level, a solid continuous platform must be constructed.

The header may rest on the top metal spacers, but must not be notched to fit around them.

Consult all local codes.

6

44 ¹⁄₂"

15"

13¹ ₄"

29 ³⁄₈"

12¹⁄₂"

6"

⁵⁄₈"

Top View

Figure 10