PROBLEM

CAUSE

CORRECTION

 

 

 

 

 

Motor will

Check valve is

Remove and clean, or replace.

not run.

 

stuck open.

 

 

(con’t)

Loose electrical

Check wiring connection inside

 

 

 

connections.

 

pressure switch and terminal box

 

 

 

 

area.

 

Possible

Return to an Authorized Warranty

 

 

defective

 

Service Center for inspection or

 

 

capacitor.

 

replacement if necessary.

Paint spray on • Have checked at an Authorized

internal motor Warranty Service Center. Do not

parts.operate the compressor in the paint

 

spray area. See flammable vapor

 

warning.

• Possible

• Have checked at an Authorized

defective

Warranty Service Center.

motor.

 

Fuse Blown, 1.Check fuse box for blown fuse and

circuit breaker replace. If necessary, reset circuit

tripped.breaker. Do not use a fuse or circuit

breaker with higher rating than specified for your particular branch circuit.

 

 

2.Check for low voltage conditions

 

 

and/or proper extension cord.

 

 

3.Disconnect the other electrical

 

 

appliances from circuit or operate

 

 

the compressor on its own branch

 

 

circuit.

 

• Pressure

• Bleed the line by pushing the lever

 

unloader valve

on the pressure switch to the "off"

 

on pressure

position; if the valve does not open,

 

switch has not

replace it.

 

unloaded head

 

 

pressure.

 

 

 

 

Regulator

Dirty or damaged

Replace regulator.

knob has

regulator internal

 

continuous

parts.

 

air leak.

 

 

Regulator

 

 

will not

 

 

shut off at

 

 

air outlet.

 

 

Page 16

Page 16
Image 16